BAR SHEARING STATION
SPARTAN IRONWORKER
G-4
© MARVEL MFG. CO., INC. MANUAL
PL/OMIW-2CYL-V2
(08//07)
The guide/guard is held in place by the two hand
knobs.
3.
Remove the four socket head cap screws
(B) that hold the blocks in place.
Four socket head cap screws (B) hold the blocks
in place.
4.
Remove the stationary blade.
5.
Install a new stationary blade.
6.
Re-install the blocks removed in step 3.
7.
Continue with step 3 of "Adjusting the
Stationary Blades", below.
Adjusting the Stationary Blade
The stationary blade is adjustable so the correct
clearance between the stationary blade and the
fixed blade can be achieved.
Avoid
serious
injury.
Turn off the machine's
power and lock it out before
adjusting or servicing the
machine.
1.
Turn off the main electrical disconnect
switch and lock it in the "Off" position.
2.
Remove the two hand knobs (C, previous
column) that hold the guard in place and
carefully remove the guard.
3.
Adjust screws "D" as needed to obtain
zero clearance between the moveable
blade and the stationary blade. Each screw
is locked in position by a hex nut.
Each of the adjusting screws (D) is locked in
position by a hex nut.
Important: When properly adjusted there
should be no clearance between the moveable
and stationary blades, however, they must not
be tightly pressed against each other.
4.
Re-install the guide / guard.
MOVEABLE BLADE
The moveable blade needs to be replaced when
the work piece develops burrs as a result of the
shearing process, or when the blade shows visible
signs of wear.
Avoid serious injury. Turn off
the machine's power and lock
it out before adjusting or
servicing the machine.
1.
Turn
off
the
main
electrical disconnect switch and lock it in
the "Off" position.
WARNING
WARNING
C
B
B
D