Copyright by Servizio Clienti ANGELO PO Spa
94
5.4.
Gas Test
5.4.1.
Preparing for the testing phase
During
testing it is necessary to prepare the appropriate tools, before entering the “gas
testing” procedure.
5.4.2.
Gas Change
All equipment comes from the company tested and regulated to Natural Gas (G20), if in
use it is necessary to adapt to a different type of gas, proceed as follows:
1. Gas nozzle replacement: loosen the gas pipe (photo 1), remove the Methane (G20)
nozzle and place the replacement nozzle using a CH24 wrench (photo 2), then
tighten the pipe again. The nozzle, reaching the stop, will also serve as gasket. The
nozzle must be assembled as shown in photo 3.
photo 1
photo 2
photo 3
Summary of Contents for ANGELO PO ACT.O
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Page 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Page 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Page 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Page 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Page 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Page 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Page 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Page 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Page 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Page 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Page 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Page 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...