Copyright by Servizio Clienti ANGELO PO Spa
101
7:
STEP 2
-
in this step it is forbidden to act on the valve adjustment
-
check stability of the maximum
-
check combustion (CO, CO
2
) of the maximum
-
enter values on the installation report
8:
STEP 3
-
in this step it is forbidden to act on the valve adjustment
-
check correct re-ignition
-
check stability of the minimum when hot
-
check combustion (CO, CO
2
) of the minimum when hot
-
enter values on the installation report
9:
END. The date of the new test will appear
Summary of Contents for ANGELO PO ACT.O
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Page 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Page 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Page 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Page 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Page 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Page 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Page 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Page 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Page 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Page 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Page 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Page 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...