E06:40
the W phase is in short with GND.
check the correct connection of the motor
and that the W power supply phase of the
motor is not shortened with the GND
E06:41
excessive current between the UV phases
check the correct connection of the motor
and that the U and V power supply phases
of the motor are not shortened between
them
E06:42
excessive current between the UW phases
check the correct connection of the motor
and that the U and W power supply phases
of the motor are not shortened between
them
E06:43
excessive current between the VW phases
check the correct connection of the motor
and that the V and W power supply phases
of the motor are not shortened between
them
E06:64
admitted current limit exceeded of 150% for
1 minute or of 200% for 3 seconds
check that the motor is not stalled due to
external reasons or that it is subject to an
external braking action
E06:70
fault detected in the inverter power supply
section
check the power supply voltage of the
inverter (230VAC)
E06:71
excessive communication errors
check that the serial line connection cable
is correctly connected.
E06:81
communication interruption
check that the serial line connection cable
is correctly connected.
E06:100
checksum error inside inverter
replace the inverter
E06:122
errors detected in the inverter control section
replace the inverter
E06:255
inverter stopped
check connection between terminal 1 and
terminal 11 on the inverter.
Summary of Contents for ANGELO PO ACT.O
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Page 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Page 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Page 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Page 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Page 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Page 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Page 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Page 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Page 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Page 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Page 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Page 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...