The screens show the parameters that regulate the blower (Minimum speed, Maximum
speed, Ignition speed), as well as the speed to be reached (set-point) and the real speed.
Check that ignition takes place at the correct speed and that the minimum and maximum
speeds reached match those set. If an incorrect operation is detected or combustion
values not within the indicated ranges are found, intervene as described in paragraph
5.4.3.
5.4.6.
Recommended combustion values
Below are the combustion values (CO
2
, CO) recommended by “Angelo Po”. We
recommend respecting these values as much as possible.
It is recommended to carry out the measurement after the flame has stabilised 2-3
minutes. In fact, when ignited, CO values could be higher, thus distorting the
measurement. Even if well regulated, the system should have CO values much lower than
100 ppm, if higher intervene as described in the following paragraph.
AT61G
CO2%
Range CO2%
CO ppm
G20
minimum
8.8%
± 0.8
0-100
Maximum
10.4%
± 0.8
0-100
G25
minimum
9.0%
± 0.8
0-100
Maximum
9.4%
± 0.8
0-100
G25,1
minimum
10.0%
± 0.8
0-100
Maximum
10.4%
± 0.8
0-100
G25,3
minimum
9.7%
± 0.8
0-100
Maximum
9.9%
± 0.8
0-100
G30
minimum
12.4%
± 0.8
0-100
Maximum
11.6%
± 0.8
0-100
G30 50mbar
minimum
12.6%
± 0.8
0-100
Maximum
11.8%
± 0.8
0-100
G31
minimum
11.2%
± 0.8
0-100
Maximum
11.5%
± 0.8
0-100
Summary of Contents for ANGELO PO ACT.O
Page 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Page 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Page 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Page 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Page 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Page 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Page 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Page 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Page 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Page 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Page 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Page 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Page 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Page 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...