Page 1: ...Henkel Inc P O Box 1322 Hammond LA 70404 985 345 2171 www keenovens com ...

Page 2: ...rmined it to be defective under the terms of this warranty The warranty covers only equipment manufactured by Henkel Inc and does not extend to transportation installation or replacement charges at the buyers facility nor does it apply to any other equipment of another manufacturer used in conjunctions with Henkel Inc equipment No other warranty expressed or implies exists beyond that included in ...

Page 3: ...onal injury follow the guidelines below Before connecting unit to a power source be sure the voltage supplied is the same as that specified on the name plate of the unit Check outlet to ensure proper grounding of the electrical cable Have a licensed electrician check the A C power outlet if you are not sure Use this unit for its intended purpose as described by literature Make sure power cord is l...

Page 4: ...e oven to a fused disconnect of proper voltage and amperage Load oven with desired amount of electrodes Switch on power to oven Set over temperature controller higher than temperature controller s set point Adjust temperature controller set point to desired temperature Refer to the Controller User s Manual for instructions in tuning controller All units are supplies with a UL listed SJ power cord ...

Page 5: ...Replace fuses 5 Check input and output voltages on over temperature and temperature controller for proper voltage If input voltage is not present check wiring If input voltage is present and there is no output voltage replace or repair controller 6 If output voltage is present check for voltage at contactor coil controlled by over temperature controller If voltage is not present check wiring If vo...

Page 6: ...tighten set screws 5 Replace electrical leads on controller terminals as per wiring diagram Note When attaching thermocouple leads to controller the negative lead wire has red insulation and the positive lead wire has white insulation 6 Check to be sure all electrical leads are on proper terminals and are secure Replace control box cover plate CHANGING THE CONTACTOR 1 Disconnect oven from power so...

Page 7: ...ctorial drawings below for repair parts Model KHT 900 Repair Parts List ITEM QUANTITY DESCRIPTION PART NUMBER 1 1 Door Latch 430110 2 1 Grab Handle 430109 3 2 Vent Plug 490108 4 2 Handy Box 301033 5 2 Pilot Light 240 V 301085 480 V 301101 6 1 Temperature Control 301001 7 1 Power Cord 301014 8 6 Element 240V 1000 W 301026 480V 1000W 301029 9 1 Cord Protector 301041 1 Contactor 301008 1 Solid State ...