22
One Chirp
Two Chirps
Three Chirps
Four Chirps
Button
LED One Pulse
LED Two Pulse
LED Three Pulse
LED Four Pulse
(Factory Default Setting)
Stage 2: Remote Start Operation Programming
In this mode you will program the type of engine starting detection you want to use in your installation. There are
3 types available:
1. Tachometer (RPM) Detection: (Most reliable and recommended) This type of detection requires
a hard wire connection to the vehicles ignition coil.
2. Voltage Detection: This method detects the drop and rise in the battery voltage when the vehicle is started
by remote. This type of detection requires a solid main power input connection but it does not require any
additional hard wire connections.
3. Elapsed Timer: This method is the easiest for installation but is not always the best method for year round
usage (Summer and winter). To operate this method, you will program a specific time window for the remote
start unit to crank the engine. Battery strength, environment and the aging process of the vehicle may require
the timer to reset from time to time or season to season.
Entering Stage 2 Remote Start Operation Programming
Remote Start Operation and Feature Programming (Stage 2)
Before 15 seconds has passed, push and release the valet
switch nine (9) times then push the valet switch a tenth
time and hold it down until five (5) short chirps/beeps +
one (1) long chirp beep is heard then release it. You are
now in stage 2 remote start feature programming mode.
9X + 1X (Hold)
Step 3
Remote Start Feature Programming
Use the transmitter buttons as illustrated to adjust the features required. Keep re-pressing the transmitter button that
relates to the feature you want to adjust until the correct amount of chirp/beeps is heard. Move on to the next feature.
Exit the Programming Mode (3 long chirps and 3 parking light flashes to confirm this exit)
Tachometer
Checking Type
RPM Learning
Start Timer:
0.6 second (1 chirp)
0.8 second (2 chirps)
1.4 second (5 chirps)
2.0 second (8 chirps)
1.0 second (3 chirps)
1.6 second (6 chirps)
3.0 second (9 chirps)
1.2 second (4 chirps)
1.8 second (7 chirps)
4.0 second (10 chirps)
Step 2
Voltage Checking
Type
Timer
Checking Type
Low Check Level
High Check Level
Start or Stop the System for Testing & Adjusting
Turn the ignition switch from the OFF position to the
ON position 3 times leaving it in the OFF position
the third time.
Step 1
OFF
ON
3X
+
+
"TEST" Mode for Zone 2
Instant Trigger & Zone 3
Door Trigger
"TEST" Mode for
Zone 1 & Zone 4
(2 Stage Shock Sensor)
Exit: Press the button on the transmitter. 3 long chirps and 3 parking light flashes confirms exit.
-
M8A-IM.qxp 4/26/05 15:56 Page 22