When the parametric equalization filter type is selected as Band-Pass Q, by rotaing “PM1” encoder,
user can enter the setting interface 11 of current output parametric equalization filter:
By using “PM2” or “PM3” encoder, it is possible to set current output PEQ filter’s frequency from
the range of 20Hz to 20kHz.
By rotaing “PM1” encoder again, user can enter the setting interface 12 of current input
parametric equalization filter:
By using “PM2”, it is possible to set the gain of current parametric equalization filter from -15dB to
+15dB. By using “PM3” encoder, it is possible to set the Q factor of current parametric
equalization filter from 4 to 104.
When the parametric equalization filter type is selected as Notch Filt, by rotaing “PM1” encoder,
user can enter the setting interface 13 of current output parametric equalization filter:
By using “PM2” or “PM3” encoder, it is possible to set current output PEQ filter’s frequency from
the range of 20Hz to 20kHz.
By rotaing “PM1” encoder again, user can enter the setting interface 14 of current input
parametric equalization filter:
By using “PM2” or “PM3” encoder, it is possible to set the Q factor of current parametric
equalization filter from 4 to 104.
When the parametric equalization filter is selected as All Pass 1, by rotaing “PM1” encoder, user
can enter the setting interface 15 of current input parametric equalization filter:
By using “PM2” or “PM3” encoder, it is possible to set current input PEQ filter’s frequency from the
range of 20Hz to 20kHz.
When the parametric equalization filter is selected as All Pass 2, by rotaing “PM1” encoder, user
can enter the setting interface 16 of current input parametric equalization filter:
Out-1 Out 1 PEQ-01
->Frequency = 20Hz
Out-1 Out 1 PEQ-01
->Gain=0.0dB Q=4
Out-1 Out 1 PEQ-01
->Frequency = 20Hz
Out-1 Out 1 PEQ-01
->Gain=Fixed Q=4
Out-1 Out 1 PEQ-01
->Frequency = 20Hz
Summary of Contents for DPA480