34
D00619EN
-
v0
SWING OPERATOR
-
INSTALLATION MANUAL
TYPE
PAR
.
VALUE
OPERATION
5
-
ELECTRONIC
LOCK
WITH
AU-
TOMATIC
RESET
10
5
See Fig. 32
-
Electronic lock which, when powered, frees the leaf to move.
It resets by cutting power to the lock when the leaf opens more than 10°.
It requires a door jolt freeing device in order to make it easier to unlock
the leaf.
11
RANGE: 0÷9
[t=100÷1000 ms]
6
-
ELECTRO
-
MAGNETIC
(
MAGLOCK
)
WITH
DELAY
10
6
See Fig. 33
-
A magnet that, when powered, keeps the door locked closed
and, when disconnected, frees it to move. It does not require a door jolt free-
ing device. The magnet is powered again after the leaf is completely closed.
11
RANGE: 0÷9
[t=200÷2000 ms]
6.2
A
Fig. 30.
Fig. 31.
Fig. 32.