28
D00619EN
-
v0
SWING OPERATOR
-
INSTALLATION MANUAL
CARACTERÍSTICAS MECÁNICAS
5.16 Dip
-
Switch Management
There is a dip
-
switch on the electronic card with 8 positions for configuring the functionality and ON
-
OFF type basic
operations. These settings are detected and memorised after a reset, and the possible dip
-
switch variations during operation
are not taken into account:
CARACTERÍSTICAS MECÁNICAS
5.17 Display Management
The two seven
-
segment displays shown in Fig. 27 and located on the electronic card with 4 buttons, control the main
parameters and the advanced options for managing the operator in various types of installation.
To correctly view the display, configure the jumper according to the side which the door will open, indicated in Fig. 27.
It can be programmed as follows:
1.
Select the parameter which is to be modified with the [+] and [
-
] keys; during this phase the display shows the
indicated parameter. Pressing the [ESC] key exits the parameter selection phase, pressing [ENT] enters the
parameters view/edit phase.
2.
The display flashes with the actual parameter value. The value can be changed using the [+] and [
-
] keys;
pressing the [ESC] key returns to the parameter selection phase without modifying the value, and pressing the
[ENT] key changes the value and returns to the parameter selection phase.
3.
During the parameters selection/edit phase there is an active timeout; if no keys are pressed for a period of
10 seconds, it exits the programming phase.
4.
In order to confirm the operational commands, it is necessary to press and hold the [ENT] key for 5 seconds,
after which the display returns to the parameter selection phase automatically.
ID
DESCRIPTION
SETTING
DEFAULT
01
Opening speed
RANGE: 20°/s ÷ 70°/s
(Adjustable by amounts of 5°/s)
60
02
Closing speed
RANGE: 20°/s ÷ 40°/s
(Adjustable by amounts of 5°/s)
20
03
Normal stopping time
RANGE:
0 ÷ 60 seconds (Adjustable by amounts of1s);
62: 2 min
63: 3 min
64: 4 min
0
04
Disabled persons/Low Energy
stopping time
RANGE: 5 ÷ 60 seconds (Adjustable by amounts of1 second)
(Only active when
aux is
set to 0)
5
DIP
PARAMETER
VALUE
DEFAULT
1
Arm type
OFF
Articulated
OFF
ON
Rigid
2
Mode
LOW ENERGY (LOW ENERGY LEVEL)
OFF
Normal
OFF
ON
Low Energy
3
Mode
PUSH&GO
OFF
De
-
activated
OFF
ON
Activated
4
Mode
KEY entry
OFF
Bistable
OFF
ON
Monostable
5
Actuator type
OFF
VectorM
OFF (M)
ON (S)
ON
VectorS (Spring)
6
Return close in non
-
manual mode
OFF
Motorised return close
OFF
ON
Return close by spring
7
Action after collision during closing by spring
OFF
Another motorised opening is not
performed
OFF
ON
Another motorised opening is performed
8
Unused
OFF
OFF
ON
Summary of Contents for VECTOR
Page 1: ...Installation Manual VECTOR Operator ...
Page 15: ...14 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 A 5 4 B Fig 4 Fig 5 D A B E C F ...
Page 16: ...15 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 C 5 4 D Fig 6 Fig 7 A A A A ...
Page 19: ...18 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 5 A 5 5 B Fig 12 Fig 13 A A ...
Page 47: ...46 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL CARACTERÍSTICAS MECÁNICAS 10 4 Notes ...