![Manusa VECTOR Installation Manual Download Page 34](http://html.mh-extra.com/html/manusa/vector/vector_installation-manual_1723975034.webp)
33
D00619EN
-
v0
SWING OPERATOR
-
INSTALLATION MANUAL
6.2.2 Management of Electronic Locks
ID
DESCRIPTION
SETTING
DEFAULT
09
Electronic lock control voltage
(1)
0 = 12 VDC
1 = 24 VDC
0
10
Types of electronic lock
(2)
0 = Not used
1 = Electronic lock with mechanical reset when closed again
2 = Electromagnetic (maglock) (24VDC only)
3 = Electronic lock
4 = Motorised locked
5 = Electronic lock with automatic reset
6 = Magnetic (maglock) with delay (24VDC only)
0
11
Impulse duration or opening delay
(3)
RANGE: 0 ÷ 9
The time depends on the type of electronic lock
2
12
Closing force of the electronic lock
(4)
RANGE: 0 (min.) ÷ 9 (max.)
5
14
Electronic lock activation according to
the selected logic
(5)
0 = Deactivated
1 = One Radar
2 = Two Radars
3 = One Radar and two Radars
3
15
Configuration of auxiliary input 1
4 = Lock Release Feedback
(6)
5 = Lock Release Control
(7)
0
16
Configuration of auxiliary input 2
4 = Lock Release Feedback
(6)
5 = Lock Release Control
(7)
1
17
Configuration of
auxiliary output 1
5 = Lock control repetition
0
18
Configuration of
auxiliary output 2
5 = Lock control repetition
1
(
1
) The lock can be operated with 12 and 24 VDC (Parameter 09) with a maximum power of 15 W. Maglocks only operate
with 24 VDC.
(
2
) The following types of locks are expected to be compatible:
TYPE
PAR
.
VALUE
OPERATION
1
-
ELECTRON-
IC
LOCK
WITH
MECHANICAL
RESET
WHEN
CLOSED
AGAIN
10
1
See Fig. 28
-
Electronic lock that when powered in impulsive mode, the leaf is
unlocked and the lock is automatically reset when it closes. It requires a door
jolt freeing device in order to make it easier to unlock the leaf.
11
RANGE: 0÷9
[t=50÷500 ms]
2
-
ELECTRO
-
MAGNET
(
MAGLOCK
)
10
2
See Fig. 29
-
If the magnet is powered, it keeps the door locked; when discon-
nected, the door may move freely. It does not require a door jolt freeing device.
The magnet is powered again before the door is fully closed to enable it to
close completely.
11
RANGE: 0÷9
[t=200÷2000 ms]
3
-
ELECTRON-
IC
LOCK
10
3
See Fig. 30
-
Electronic lock that when powered, moves a bolt which keeps the
door locked. When disconnected, the bolt goes up and the leaf can move
freely. It requires a door jolt freeing device in order to make it easier to unlock
the leaf. The magnet is powered again when the door is closed.
11
RANGE: 0÷9
[t=200÷2000 ms]
4
-
MOTORISED
LOCK
10
4
See Fig. 31
-
Electronic lock with electronic starter motor; when powered, it
retracts the locking arm allowing the leaf to move freely. It requires a door jolt
freeing device in order to make it easier to unlock the leaf. The electronic lock
disconnects when the door is closed.
11
RANGE: 0÷9
[t=500÷5000 ms]
Summary of Contents for VECTOR
Page 1: ...Installation Manual VECTOR Operator ...
Page 15: ...14 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 A 5 4 B Fig 4 Fig 5 D A B E C F ...
Page 16: ...15 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 C 5 4 D Fig 6 Fig 7 A A A A ...
Page 19: ...18 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 5 A 5 5 B Fig 12 Fig 13 A A ...
Page 47: ...46 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL CARACTERÍSTICAS MECÁNICAS 10 4 Notes ...