27
D00619EN
-
v0
SWING OPERATOR
-
INSTALLATION MANUAL
5.15
C
Fig. 26.
WARNING: move away from the sensors so that they do not detect any obstacle and so that, when they deactivate,
they allow the acquisition process to finish. If they do not deactivate, the procedure will remain blocked and it can be
aborted by pressing the ESC key.
When the procedure is finished, the display will show one of four values depending on the configuration detected:
ID
CONFIGURATION
DESCRIPTION
S0
No supervised sensor detected
No sensors detected, or the sensors that may be connected are managed
as normal sensors, not as supervised sensors.
S1
Supervised sensor only during opening
The supervised sensor is managed only during opening.
During the closing phase there is no sensor, or the sensor is man-
aged as a normal sensor.
S2
Supervised sensor only during closing
The supervised sensor is managed only during closing. During the opening
phase there is no sensor, or the sensor is managed as a normal sensor.
S3
Supervised sensor both during opening
and closing
The supervised sensor is managed both during opening and closing.
The value will remain on the display until one of the following keys is pressed:
•
ENT: To accept the detected configuration, ensuring that it corresponds effectively with the actual configuration of the
sensors connected to the operator.
•
ESC: To reject the detected configuration and return to the E6 error state.
WARNING:
Never accept the detected configuration if it does not coincide with the actual configuration of the
sensors connected to the operator. This may trigger highly hazardous situations or cause the operator to
malfunction
.
WARNING:
The automatic acquisition procedure of supervised sensors should be repeated every time the
configuration of the sensors connected to the operator is changed.
WARNING:
In the case of the Double Vector (2 leaves) operator, THE AUTOMATIC ACQUISITION PROCEDURE
OF SUPERVISED SENSORS SHOULD BE CARRIED OUT ON BOTH ELECTRONIC CARDS (MASTER AND
SLAVE).
The acquisition procedure can be repeated at any time using the LS parameter (refer to section ‘Display Management’).
At start
-
up, the display shows the firmware version of the card, and then the configuration of the sensors in memory (S0; S1; S2;
S3), for 2 seconds.
If the supervision of a sensor malfunctions, the display will show the flashing value of this sensor (S1: opening safety device; S2: closing
safety device; S3: both). This signal will end once normal supervision has been re
-
established.
L
O
C
K
G
N
D
D
A
T
A
PW
F
R
S
T
O
U
T
15
VD
C
C
O
M
A
U
X
-
I
N
2
A
U
X
-
I
N
1
S
T
A
R
T
2
S
T
A
R
T
1
C
O
M
K
EY
SA
F
E
-
C
L
O
SE
SA
F
E
-
O
P
EN
C
O
M
A
U
X
–
O
U
T
2
A
U
X
–
O
U
T
1
A
B
A
B
+
-
-
+
Summary of Contents for VECTOR
Page 1: ...Installation Manual VECTOR Operator ...
Page 15: ...14 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 A 5 4 B Fig 4 Fig 5 D A B E C F ...
Page 16: ...15 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 C 5 4 D Fig 6 Fig 7 A A A A ...
Page 19: ...18 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 5 A 5 5 B Fig 12 Fig 13 A A ...
Page 47: ...46 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL CARACTERÍSTICAS MECÁNICAS 10 4 Notes ...