To install the Double VECTOR with the prolongation kit, follow the steps below:
1. Disassemble all of the components attached to the main profiles of each operator.
2. Support against a flat surface the two operator profiles by the ends and against the joining profile, centring them.
3. Insert into the main profile of each operator the lower tab of the joining heads, located at the ends of the central
profile, such that the three profiles are aligned (See Fig. 34)
WARNING: Keep the profiles oriented as indicated in Fig. 34, so that the black heads are placed at the ends.
4. Press the pins (Fig. 34) so that the profiles are joined together.
5. Place the profiles on the wall and make holes suitable for the fixing screws used, following the instructions and the
‘Positioning Levels’ set forth in the previous chapters according to the type of arm to be used.
6. Connect the two program switch terminal plates so the two cards can communicate and so that the operator
operates correctly. (Fig. 33)
7. Re
-
assemble all the components for each one of the Vectors; to do so, insert into the hinge ends of the Master
operator the head located on the prolongation kit with the on switch and logic settings program switch, while on the
opposite part only the head with the on switch.
WARNING: In both cases, select the Master leaf and the Slave leaf before making the connections.
By convention:
MASTER LEAF: First to open, last to close (in the case of a delay) SLAVE LEAF: Last to open, First to close (in the case of a delay)
In both cases, to configure the electronic cards, it is necessary to follow the steps below:
1. It is necessary to configure the corresponding electronic cards using display settings (see section ‘Managing
Operating Parameters of the Display’):
•
Configure parameter 13 =1 on the MASTER card.
•
Configure parameter 13 =2 on the SLAVE card.
Even for synchronised movement (the leaves open and close at the same time without any delay), it is always necessary to
configure one Master operator and another one as Slave.
WARNING: The two operators must be connected on the same power line and there should be no switches or fuses
between the two operators. The existing peripherals should be connected (KEY, START 1 y START 2) only to the
MASTER. The safety sensors (SAFE OPEN and SAFE CLOSE), in contrast, should be connected and controlled
separately by both cards.
To install the Double VECTOR with two individual Vectors, follow the steps below:
1. Disassemble all of the components attached to the bases of each operator.
2. Attach the bases of each operator to the wall making the necessary holes for each type of screw used in mounting
the operator; follow the instructions and the ‘Positioning Levels’ indicated in the previous chapters, depending on
the type of arm to be used.
3. Connect the two program switch terminals so the two cards can communicate and the operator functions correctly.
(Fig. 33)
4. Re
-
assemble all the components for each one of the Vectors disconnecting the logic settings program switch from
the slave operator (B).
Summary of Contents for VECTOR
Page 1: ...Installation Manual VECTOR Operator ...
Page 15: ...14 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 A 5 4 B Fig 4 Fig 5 D A B E C F ...
Page 16: ...15 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 4 C 5 4 D Fig 6 Fig 7 A A A A ...
Page 19: ...18 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL 5 5 A 5 5 B Fig 12 Fig 13 A A ...
Page 47: ...46 D00619EN v0 SWING OPERATOR INSTALLATION MANUAL CARACTERÍSTICAS MECÁNICAS 10 4 Notes ...