© Welbilt, Inc.
NOTE: With Continuity DO NOT Change Probe!
Without Continuity, the Probe is Defective
Water Level Probe Diagnostics
158
Indigo NXT Ice Machine Troubleshooting Tips
Step 5
– Unplug the probe from the
board and pull the water level probe
out of its mount. Ohm out from the
connector to the three probes.
•
Red wire
to short probe = 0 ohms.
•
Black wire
to both long probes = 0
ohms to only one of the long probes
and infinity to the other long probe.
•
White wire
to the probe that
showed infinity to the black wire
should now show 0 ohms.
White
Black
Red
H
C
L
Short
Probe