© Welbilt, Inc.
X
Rotary Refrigeration System (Liquid Charging)
14
INDIGO NXT
T1
T2
T3
T4
HEAT
EXCHANGER
THERMOSTATIC
EXPANSION
VALVE
HARVEST VALVE
CONDENSER
COMPRESSOR
DRIER
EVAPORATOR
Receiver
(Water Cooled Only)
HIGH PRESSURE VAPOR
HIGH PRESSURE LIQUID
LOW PRESSURE LIQUID
LOW PRESSURE VAPOR
Rotary Compressor Third Port Liquid
Charging:
•
Damage may occur when
charging liquid into the front
discharge line service access port.
•
It is recommended that all Liquid
charging should be done through
the Liquid Line service access.
•
Replacement driers will have a
Schrader built into the inlet.
If no liquid line access is available (drier), install one into the liquid process tube
before recharging the ice machine.