© Welbilt, Inc.
Service Menu Navigation: Service Data
133
Indigo NXT Ice Machine Troubleshooting Tips
Service
Data
Alert Log
Manual Harvest
Control Board
Replacement
Diagnostics
Contact
Information
USB
iAUCS
Real Time
:
•
Time & Temperature
•
Inputs
•
Outputs
Data History
:
•
Current Day
•
Current Day -1
•
Current Day -2
•
Current Day -3
•
Current Day -4
•
Lifetime
•
View
•
Clear
•
ON
•
OFF
Manual Replacement:
•
Model Number
•
Serial Number
•
Cond. Serial Number
•
Confirm
USB Replacement:
•
Import to ice machine
•
Export to USB
Control Board:
•
Enable Relays
•
Self-Check
Temperature
Sensors:
•
T1
•
T2
•
T3
•
T4
•
T5
•
T6
•
T7
Inputs:
•
Curtain SW 1
•
Curtain SW 2
•
HPCO SW
•
ITP FFT 100HZ
•
ITP FFT 120HZ
•
WLP Low
•
WLP High
User Interface:
•
Push button
•
Display
•
Calibrate Screen
•
Global Locator
•
Edit Contact Information
•
Upgrade Firmware
•
Export Data
•
Manually activate iAUCS
Pump
Real Time
:
Data History
:
Data
•
Current Day
•
Current Day -1
•
Current Day -2
•
Current Day -3
•
Current Day -4
Lifetime
Time & Temperature
•
Phase/State
(Pre-Chill, Freeze,
Harvest, etc…)
•
Timer (00:00:00) Phase/
State
•
T-1 Temperature
•
T-2 Temperature
•
T-3 Temperature
•
T-4 Temperature
•
T-5 (Ice Level Kit)
•
T-6 (Not being used)
•
T-7 (Not being used)
Inputs
•
Phase/State
(Pre-Chill, Freeze,
Harvest, etc…)
•
Timer (00:00:00) Phase/
State
•
Curtain SW:1
•
Curtain SW:2
•
HP.CO Switch
•
ITP FFT 100HZ
•
ITP FFT 120HZ
•
Water LVL Low
•
Water LVL High
Outputs
•
Phase/State
(Pre-Chill, Freeze,
Harvest, etc…)
•
Timer (00:00:00) Phase/
State
•
Water Pump
(on/off)
•
Harvest Valve 1 (on/off)
•
Harvest Valve 2 (on/off)
•
Water Valve
(on/off)
•
Dump Valve
(on/off)
•
Comp Contactor (on/off)
•
Minimum Freeze
•
Length
•
Time of day
•
T1 Temp (Recorded at 6 minutes into Freeze cycle)
•
T2 Temp (Recorded 1 minute before the end of freeze cycle)
•
T3 Temp (Recorded at 6 minutes into Freeze cycle)
•
T4 Temp (Recorded at 6 minutes into Freeze cycle)
•
Maximum Freeze
•
Length
•
Time of day
•
T1 Temp (Recorded at 6 minutes into Freeze cycle)
•
T2 Temp (Recorded 1 minute before the end of freeze cycle)
•
T3 Temp (Recorded at 6 minutes into Freeze cycle)
•
T4 Temp (Recorded at 6 minutes into Freeze cycle)
•
Minimum Harvest
•
Length
•
Time of day
•
T1 Temp (Recorded 30 seconds into Harvest cycle)
•
T2 Temp (Recorded at 1 minute prior to previous freeze cycle end)
•
T3 Temp (Recorded 30 seconds into Harvest cycle)
•
T4 Temp (Recorded 30 seconds into Harvest cycle)
•
Maximum Harvest
•
Length
•
Time of day
•
T1 Temp (Recorded 30 seconds into Harvest cycle)
•
T2 Temp (Recorded at 1 minute prior to previous freeze cycle end)
•
T3 Temp (Recorded 30 seconds into Harvest cycle)
•
T4 Temp (Recorded 30 seconds into Harvest cycle)
•
Run Time
00:00:00, actual run time over the 24 hour period.
•
Ice Production
XXXX LBS, ice production over the 24 hour period.
•
Cycle Count
XXXX, Cycle Count (Freeze/Harvest) over the 24 hour period.
•
Potable Water
XXXX, Potable water (Ice Making) over the 24 hour period.
•
Clean Cycles
XXXX, Clean Cycles over the 24 hour period.
•
Install Date
(XX/XX/XXXX)
•
Control Board Replacement Date
(XX/XX/XXXX)
•
Control Board Manufacture Date
(XX/XX/XXXX)
•
Run Time
(Hours)
•
Cycle Count
(XXXXX)
•
Potable Water
(XXXXX)
•
Clean Cycles
(XXXXX)
Summary of Contents for Welbilt Indigo NXT QuietQube
Page 3: ... Welbilt Inc Welbilt Inc Engineered For Ease Overview INDIGO NXT 3 ...
Page 17: ... Welbilt Inc Welbilt Inc Engineered For Ease QuietQube CVD Installation INDIGO NXT 17 ...
Page 50: ... Welbilt Inc Engineered For Ease Menu Navigation Indigo NXT Ice Machines ...
Page 54: ... Welbilt Inc Indigo NXT Menu Navigation Alert 54 Touch Screen Interface Main Menu ...
Page 55: ... Welbilt Inc Indigo NXT Menu Navigation Alert 55 Touch Screen Interface Main Menu ...
Page 114: ... Welbilt Inc Welbilt Inc Engineered For Ease Troubleshooting INDIGO NXT Ice Machine 114 ...
Page 126: ... Welbilt Inc Welbilt Inc Engineered For Ease Troubleshooting Tips INDIGO NXT Ice Machine 126 ...
Page 153: ... Welbilt Inc Water Level Probe Diagnostics 153 Indigo NXT Ice Machine Troubleshooting Tips ...