J11 Connector on Control Board
Pin 1 (+)
Red
Pin 2 (-)
Black
Pin 3
Twisted Wire
Ice Thickness Probe Diagnostics
147
Indigo NXT Ice Machine Troubleshooting Tips
If the initial numbers displayed
do not
change
or initial numbers
did not
increase by 3000
during scratch test:
•
Verify the ice thickness probe connector is
properly plugged into the board ( J11 ) and
the ice thickness probe wiring is correct . If
the wiring is incorrect, replace the ITP.
10. Unplug the ITP and set a VOM to DC voltage
scale – Measure voltage across Pin 1(+) Red
Wire and Pin 2(-) Black Wire:
Premature Harvest or Freeze Up
NOTE: Please verify the ice thickness probe is plugged into the
proper position. We found that in some cases it can be plugged in
wrong, even though the plug is supposed to be a One Position plug.
Summary of Contents for Welbilt Indigo NXT QuietQube
Page 3: ... Welbilt Inc Welbilt Inc Engineered For Ease Overview INDIGO NXT 3 ...
Page 17: ... Welbilt Inc Welbilt Inc Engineered For Ease QuietQube CVD Installation INDIGO NXT 17 ...
Page 50: ... Welbilt Inc Engineered For Ease Menu Navigation Indigo NXT Ice Machines ...
Page 54: ... Welbilt Inc Indigo NXT Menu Navigation Alert 54 Touch Screen Interface Main Menu ...
Page 55: ... Welbilt Inc Indigo NXT Menu Navigation Alert 55 Touch Screen Interface Main Menu ...
Page 114: ... Welbilt Inc Welbilt Inc Engineered For Ease Troubleshooting INDIGO NXT Ice Machine 114 ...
Page 126: ... Welbilt Inc Welbilt Inc Engineered For Ease Troubleshooting Tips INDIGO NXT Ice Machine 126 ...
Page 153: ... Welbilt Inc Water Level Probe Diagnostics 153 Indigo NXT Ice Machine Troubleshooting Tips ...