53
FEATURES OF THE CABINET
The technical requisites of the cabinet are the following:
-
The cabinet and its components must be able to withstand temperatures
of up to 90°C without presenting deformities and/or surface defects.
-
the cabinet must enable the free passage of the oven connections;
-
All household kitchen units must be protected with
fire-resistant material in accordance with the standards in force
;
■
ELECTRIC CONNECTION OF THE OVEN ■
Ensure the electric current has been disconnected before connecting the oven to the
electric mains.
The oven requires single-phase alternate current 220-240 V~ 50/60 Hz, using flexible
cable. Ensure the household power supply can support the electric load of the device.
The electric safety of this appliance is only assured if the same is correctly connected to
a system having efficient earth connection, according to the legal Standards in force. In
case of permanent connection to the electric mains, apply a bipolar switch dimensioned
to the corresponding load, with opening for each contact of at least 3 mm in accordance
with the current local regulations.
In models where present, the flexible cable is supplied without plug. The plug to be
used must be suitable for the electric load of the product and must comply with the
current regulations.
The installer must ensure that the socket is suitable for the power absorbed by the oven
as indicated on the serial plate.
The connection socket must be easily accessible.