25
:$51,1*:KHQGUDLQLQJWKHIXHOEHVXUHWRVWRSWKHHQJLQHDQGFRQ¿UPWKDWWKHHQJLQHFRROV
GRZQ
7KHHQJLQHLVVWLOOKRWMXVWDIWHUVWRSSLQJWKHHQJLQH:DLWXQWLOLWFRROVGRZQ
RWKHUZLVHLWPD\FDXVHEXUQVRU¿UH
Fault location
When the machine is kept out of operation for a long time, perform the
followings:
- Drain up fuel from the fuel tank and carburetor according to the following
procedure:
1) Remove the fuel tank cap, and drain fuel completely. If there is any foreign
matter remaining in the fuel tank, remove it completely.
3XOORXWWKHIXHO¿OWHUIURPWKHUH¿OOSRUWXVLQJDZLUH
3) Push the primer pump until fuel is drained from there, and drain fuel
coming into the fuel tank.
5HVHWWKH¿OWHUWRWKHIXHOWDQNDQGVHFXUHO\WLJKWHQWKHIXHOWDQNFDS
5) Then, continue to operate the engine until it stops.
- Drain up the chain oil.
- Remove the saw chain and the guide bar.
- Clean the guide groove of the guide bar.
- Lubricate slightly on the saw chain and the guide bar.
- Remove the spark plug, and drip several drops of engine oil through the
spark plug hole.
- Gently pull the starter handle so that engine oil will spread over the engine,
and attach the spark plug.
- In general, store the machine in horizontal position. If it is not possible,
place the machine as the motor unit comes below the cutting tool. Otherwise
engine oil may leak from inside.
- Always pay attention to storing the machine in a safe place to prevent
machine damage and personal injury.
- Keep the drained fuel in a special container in a well-ventilated shade.
Attention after long-time storage
-
%HIRUHVWDUWXSDIWHUORQJWLPHVWRUDJHEHVXUHWRUHSODFHHQJLQHRLOUHIHUWR³5(3/$&(0(172)(1*,1(2,/´2LOZLOOGHWHULRUDWHZKLOH
the machine is kept out of operation.
STORAGE
Fault
System
Observation
Cause
Engine not starting or with
GLI¿FXOW\
Ignition system
Ignition spark O.K.
Fault in fuel supply or compression system, mechanical
defect
No ignition spark
STOP-switch operated, wiring fault or short circuit, spark
plug or connector defective, ignition module faulty
Fuel supply
)XHOWDQN¿OOHG
Incorrect choke position, carburetor defective, fuel supply
line bent or blocked, fuel dirty
Compression
No compression when
pulled over
Cylinder bottom gasket defective, crankshaft seals
damaged, cylinder or piston rings defective or improper
sealing of spark plug
Mechanical fault
Starter not engaging
Broken starter spring, broken parts inside of the engine
Warm start problems
7DQN¿OOHGLJQLWLRQVSDUN
existing
Carburetor contaminated, have it cleaned
Engine starts but dies
Fuel supply
7DQN¿OOHG
Incorrect idling adjustment, carburetor contaminated
Fuel tank vent defective, fuel supply line interrupted,
cable or STOP-switch faulty
,QVXI¿FLHQWSHUIRUPDQFH
Several systems may
simultaneously be
affected
Engine idling poor
$LU¿OWHUFRQWDPLQDWHGFDUEXUHWRUFRQWDPLQDWHGPXIÀHU
clogged, exhaust duct in the cylinder clogged
Drain fuel
Humidity
Summary of Contents for EY2650H
Page 262: ...262 ...
Page 263: ...263 ...
Page 264: ...Makita Corporation Anjo Aichi Japan 885326A996 www makita com ALA ...