49
© 2010 Magnum Energy, Inc.
4.0 Menu Map
Range: 0.1 to 25.5 Hrs
Accessory/TECH Menu Maps start on next page
Range: 60 VAC to 100 VAC, UPS Mode (120 VAC
to 200 VAC, UPS Mode for export models)
Range: Time, Amps , SOC
Range: 0.0 to 25.5 Hrs
.......
continued….
SETUP
1 Router
2 Inverter
3 Charger
ALL Select Setup
03D Low VAC Dropout
60 VAC
ALL View CHG Setup
Set Low VAC Dropout
60 VAC
ALL edit CHG Setup
Set Low VAC Dropout
100 VAC
ALL EDIT CHG Setup
03E Absorb Done
Time = 2.0 Hours
ALL View CHG Setup
Set Absorb Done
Time
Amps
ALL edit CHG Setup
Set Absorb Done
Time
Amps
ALL EDIT CHG Setup
Set Absorb Done
Amps
SOC
ALL EDIT CHG Setup
Set Absorb Done
Amps = 2.0 ADC
ALL edit CHG Setup
Set Absorb Done
Time = 2.0 Hours
ALL edit CHG Setup
03F Max Charge Time
Time = 0.0 Hours
ALL View CHG Setup
Set Max Charge Time
Time = 0.0 Hours
ALL edit CHG Setup
Set Max Charge Time
Time = 25.5 Hours
ALL EDIT CHG Setup
Set Absorb Done
SOC = 100%
ALL edit CHG Setup
Range: 0 to 250 ADC Range: 50% to 100%
03G Final Charge
Stage= Multi-Stage
ALL View CHG Setup
Set Final Charge
Stage=Multi-Stage
ALL edit CHG Setup
Range: Multi-Stage, Float, Silent
Set Final Charge
Stage= Float
ALL EDIT CHG Setup
Set Final Charge
Stage= Silent
ALL EDIT CHG Setup
Set DC Volts to
ReBulk 12.0 Volts
ALL edit CHG Setup
Range: 12-16 VDC (12V), 24-32
VDC (24V), 48-64 VDC (48V)
S
S
S
S
S
S
S
.........
Set Low VAC Dropout
UPS Mode
ALL EDIT CHG Setup
Set Max Charge Time
Time = 0.1 Hours
ALL EDIT CHG Setup
S
Default: 80 VAC (160 VAC for export models )
Default: 2.0 Hrs
Default: 20 ADC
Default: 100%
Default: 12.0 Hrs
Default: Multi-Stage
Figure 4-7, SETUP Button Menu Map - Charger (Page 7 of 9)
4.0 Menu Map: ME-RTR Router Control (continued)