3.0 Setup
05 BMK Setup
The ME-BMK/ME-BMK-NS (Battery Monitor Kit) accurately measures the SOC
(State Of Charge), battery voltage, and the DC amps of the battery bank.
Info:
For detailed information on the ME-BMK/ME-BMK-NS and
all its menus, refer to it’s owner’s manual (PN: 64-0013)
.
06 REM Setup
A remote control (ME-ARC50 or ME-RC50) can be used as a second location
remote in a parallel system. By plugging a remote into one of the router’s
communication ports it becomes a system monitor. No setup features are
allowed from the remote control; all setup must be done using the router.
The remote control can be plugged into any port (P1-P6), and can monitor
any port to which an inverter is connected. However, it must be first assigned
to that port in order to monitor it.
Default
-
System
will appear as the assigned port for the remote control.
System
means the remote control will monitor the SYSTEM port.
To assign a different port, press the SELECT knob and rotate to the desired
port (P1-P6). Press the SELECT knob to save the port selection.
Info:
The
REM Setup
menu is only available if a remote is
plugged into one of the router’s communication ports (P1-P6).
3.2.5 TECH Button
The TECH menu button provides access to selections that assist service
technicians in troubleshooting. It provides access to system information along
with an option that allows all system settings to be returned to the original
factory default values. See Figure 3-7 on the next page.