
Viewing Waveforms, Vectors, and Pictures
7-24
Figure 7-25. Reduced Size Waveform Display
This display offers several choices. For example, the display can show the waveform alone, the vector
alone, or both. The background of the waveform/vector can be opaque, so you cannot see the picture
through it, or it can be mixed with the picture (see Figure 7-26). To make these choices:
1.
Press the
Config
button.
2.
Select DISPLAY and then press the
Enter
button.
3.
Select SPLIT SCREEN and then press the
Enter
button.
4.
Select REDUCED SIZE DISPLAY and then press the
Enter
button or turn the knob to select
WFM, VEC, or BOTH.
5.
Select REDUCED SIZE MIX and then press the
Enter
button to toggle between ON and OFF.
Selecting OFF makes the display background opaque.
6.
Press
Clr
Mnu
to exit.
If Split Screen is on when making choices, you will see the changes taking place.
The graticules are simplified in this reduced size display. H and V Mag, H and V Position, Line Sel,
Vec. Phase, and Var. Gain all still function normally. You can choose between 1H and 2H sweeps, but
2F sweep is not available in reduced size images when both waveform and vector are displayed.
The picture is normally referenced to itself each time it is displayed, even if REFERENCE, EXT is
selected. This prevents the picture from shifting up and down, left and right, if the timing of the
external sync is very different from the displayed signal. To change the picture to external sync:
1.
Press the
Config
button.
2.
Select PICT. REF and then press the
Enter
button to select REF.
3.
Press
Clr
Mnu
to exit.
Now the reference for the picture follows the main reference, whether it is internal or external. The
menu line just above the reference is the same one you change when you press the
Blue
(2nd) button
and then the
Field Sel
botton. Note that when a vector is displayed with the picture, the picture
reference always goes to internal, regardless of the setting of PICT. REF.
Summary of Contents for MM-410
Page 16: ...About This Manual 1 4 Notes...
Page 34: ...Installation 4 6 Notes...
Page 48: ...Front Panel Operation 5 14 Notes...
Page 102: ...Viewing Waveforms Vectors and Pictures 7 30 Notes...
Page 126: ...Automatic Measurement AVM 510A 9 20 Notes...
Page 148: ...AVM 510A C For Component Measurements 12 4 Notes...
Page 158: ...Connector Pinouts B 4 Notes...
Page 162: ...Calibration D 2 Notes...