Operating the MM410/AVM-510A
6-19
To view the SC/H Phase and Color Frame:
1.
Press the
Mesmnt
button.
2.
Select WAVEFORM READOUTS and then press the
Enter
button.
3.
Select SC/H PHASE and then press the
Enter
button to turn it on or off.
4.
Select COLOR FRAME and then press the
Enter
button to turn it on or off.
5.
Press the
Clr Mnu
button to exit.
The time display in the lower-right corner shows either VITC time code, taken straight from the
signal, or the internal clock. To view this display, you have to turn it on, and then select which one you
want to display (VITC TIMECODE, INTERNAL CLOCK, or AUTO SWITCH). If you want to view
VITC, the MM-410/AVM-510A has to know which line has the time code. If you use the internal
clock, you have to set the time and date. Note that the date part of the clock is used in reporting;
however, it is not displayed on the screen.
To turn these features on and off:
1.
Press the
Mesmnt
button.
2.
Select TIME READOUT and then press the
Enter
button.
3.
Select TIME and then press the
Enter
button to turn it on or off. This controls the display of both
types of time readout.
4.
If you are going to use VITC, use the
Arrow
buttons to select VITC LINE and then turn the knob
until the number of the correct VITC line appears.
5.
Select TIME SOURCE and then press the
Enter
button to select one of the following:
–
VITC TIMECODE
the readout will always be VITC time code.
–
INTERNAL CLOCK
the readout will always be the internal clock.
–
AUTO SWITCH
the readout will be VITC if the time code is present on the designated
line. Otherwise, it will be the internal clock.
To set the internal clock:
1.
Press the
Config
button.
2.
Select OTHER and then press the
Enter
button.
3.
Select SET INTERNAL CLOCK and then press the
Enter
button.
4.
Select each of the parts of the date and time and then rotate the knob to select the current time.
5.
Set the time several seconds ahead of the current time and then select Press To Set. When that time
appears, press the
Enter
button. The internal clock will be set to that time and date, and you will
see the time display updated.
Summary of Contents for MM-410
Page 16: ...About This Manual 1 4 Notes...
Page 34: ...Installation 4 6 Notes...
Page 48: ...Front Panel Operation 5 14 Notes...
Page 102: ...Viewing Waveforms Vectors and Pictures 7 30 Notes...
Page 126: ...Automatic Measurement AVM 510A 9 20 Notes...
Page 148: ...AVM 510A C For Component Measurements 12 4 Notes...
Page 158: ...Connector Pinouts B 4 Notes...
Page 162: ...Calibration D 2 Notes...