47
Note
:
Until the Data Key has finished initializing, a message will appear on the display
“Data Key Not Ready”. If no Data Key is installed, the ERROR message will also
be displayed.
12.3 Delete
Welds
The Delete function is used to remove unwanted programs from memory.
Use Encoder to select a weld program. Press Delete Soft Key.
This feature can also be used to Delete welds from a Data Key, if the Key has been installed
and initialized. Program on the Data Key will be numbered 100 and higher.
Note
:
Only existing weld programs are displayed in the Delete screen.
12.4 Print
Welds
Select Weld To Print: using Encoder. Select Print To: Memory, Printer, Both. Select Short
Form (parameters only) or Long Form (parameters, as well as all procedure information and
notes).
Definitions:
•
Memory: Internal Memory
•
Print: Transfer files for printing to integral printer,
or
Transfer to DataKey for printing
using a PC.
•
Automatic Printout: set to Yes, the printout will automatically occur following each weld