46
12.0
MENU
Press Menu Soft Key. Most functions will be password protected if this option is selected.
12.1
Copy Welds (Power Source Internal Memory)
It is frequently desirable to copy an existing weld program as a starting point for creating a
new weld program for a different tube size, using the editing feature.
Enter the desired program numbers for Source Weld and Destination Weld then press the
Copy Soft Key. The Copy function allows the user to copy one weld program within the
power source’s internal memory. (For example, an existing Weld Number 2 could be copied
to Weld Number 10, assuming no Program Number 10 exists.) The program will not be
deleted from Weld Number 2; two copies of the program now exist.
To Copy a weld program, the Source Weld and Destination Weld Program Numbers must be
entered. Select the Source or Destination weld by using the arrow keys and then press
Enter. Use the Encoder to change the values for Source and Destination. Once values are
set to the desired weld numbers, press Copy Soft Key.
Weld Numbers 1-99 are files stored in the internal memory of the Power Source.
12.2
Copy/Transfer Files to Data Key
To Transfer a Weld Program from internal memory to a Data Key (or vice versa), install a
Data Key in the USB connector at the top of the Pendant.
The Data Key will require approximately 1 minute to initialize at which time, the LED on the
side of the key will slowly pulse. When it is ready, it will blink rapidly 5 times. To transfer a
weld program; select the Source and Destination Weld Numbers. Weld programs 100 and
above indicate a program to be stored (or presently stored) on the Data Key.