37
Input all information and select the number of Passes and Levels. Move the Cursor to the
desired line and use the Encoder (or Enter switch plus Encoder for O.D. and Wall Thickness.)
The Guide Ring Factor is scribed on the face of each Guide Ring (See Table 10.3). Select
Program Mode (Time or Position-based)
TABLE 10.3: D-HEAD GUIDE RING SPEED FACTORS (REF 102176 &102189)
D-HEAD GUIDE RING SPEED
FACTORS (REF 102176 & 102189)
5/19/2004
GUIDE RING
SIZE
PIPE/TUBE
NOM. OD
GUIDE
RING
FACTOR
D
N
"GRF="
1-3/4 TUBE
1.750
7.5
1-1/2" PIPE
1.900
8.0
2" TUBE
2.000
8.5
2-1/8" TUBE
2.125
9.0
2" PIPE
2.375
9.5
2-1/2" TUBE
2.500
10.0
2-1/2" PIPE
2.875
11.0
3" TUBE
3.000
11.5
3-1/4" SPECIAL 3.250
12.5
3" PIPE
3.500
13.0
3-1/2" PIPE
4.000
14.5
4" PIPE
4.500
16.0
4-1/2" PIPE
5.000
18.0
5" PIPE
5.563
19.5
6" PIPE
6.625
23.0
7-5/8" TUBE
7.625
26.5
8" PIPE
8.625
29.5
10" PIPE
10.750
36.0
12" PIPE
12.750
42.5
14" PIPE
14.000
46.5