All risk situations that require operator intervention are
analyzed by the control module and sent to the interface
module that emits then, according to the degree of risk, alarms
or alerts needed.
General Characteristics
•
Complete ventilation platform, with low weight and
volume, integrating the pneumatic and electronic
modules.
•
Graphical interface with high-resolution color screen
(up to XVGA), touch and single button (spin and
confirm) for data entry.
•
Color display of 15 inches.
•
Digital technology, with the last generation
embedded processor, applied to the electronic
control system flow and pressure.
•
Graphical interface completely intuitive, allowing
operations through the touch screen or spin and
confirm button.
•
Recording of all parameters used by the last patient,
allowing the ventilator to shut down without the need
for adjustments when turns it on.
•
Reading the regulated gas pressure (O2 and
compressed air).
•
No need to use regulator valves for O2 and
compressed air if the gas supply is within the
pressure range specified in this manual.
•
Flow and pressure readings in the breathing circuit.
•
Precise reading of the O2 concentration in the
mixture of gases delivered through the galvanic cell,
or optionally, non-consumable paramagnetic cell.
•
Automatic altitude compensation.
•
Single distal flow sensor for all types of patient.
•
Complete monitoring of various ventilation
parameters.
•
Quick access functions:
o
Standby Mode
o
Mute alarm
o
100% O
2
or O
2
suction
o
Cycle for manual breath
o
Inspiratory pause
o
Expiratory pause
•
Nebulizer synchronized with the patient's inspiration
and volume compensation and FiO2 by software
that maintains the volume and FiO2 adjusted.
•
Tracheal Gas Insufflation synchronized with the
expiration of the patient.
•
Automatic weaning feature that when detect a
particular sequence of inspiratory efforts suspends
the backup ventilation and resumes the set
ventilation mode.
•
Trend graphs with memorization of events in the last
hours of ventilation (up to 24 hours, depending on
the model).
•
BICOLOR LED as connection indicator to electrical
supply; green when equipment is connected and
blue when equipment is being supplied only by
batteries.
•
Input port to an electric power supply 100-240 VAC
~ 50-60 Hz.
•
Input port to an external source 15 V / 4 A (optional).
•
Connectivity with personal computer by means of
standard output RS232.
•
Remote assistance and diagnostics - Magnamed
(ARM).
•
These equipments shall be operated only by qualified and properly trained professionals for