214733
151
Revision A
1022324
A
B
C
D
E
F
G
H
Figure 4.81: Knife/Reel/Auger Drive Multicoupler
6.
Clean multicouplers and receptacles to prevent
contamination.
7.
Push button (A) on rear multicoupler receptacle and rotate
handle (B) away from windrower.
8.
Open cover (C) and position multicoupler (D) onto
receptacle. Align pins in coupler with slots in handle (B),
and rotate handle toward windrower so that coupler is
locked onto receptacle and button (A) snaps out.
9.
Push button (E) on front multicoupler receptacle and rotate
handle (F) away from windrower.
10. Open cover (G) and position multicoupler (H) onto
receptacle. Align pins in coupler with slots in handle, and
rotate handle toward windrower so that coupler is locked
onto receptacle and button (E) snaps out.
1023406
A
B
1
2
A
C
Figure 4.82: Knife Pressure Hose Positions
1 - Hose in Storage Position (Rotary Configuration)
2 - Hose to Knife Pressure Receptacle (Auger/Draper Configuration)
M1170 configured with R1 Hydraulic Drive Bundle (B6621):
11. If switching from a rotary header to an auger header,
remove hose (A) from storage location (B) and connect to
knife pressure receptacle (C) on frame.
Summary of Contents for M1170
Page 3: ...Declaration of Conformity 1026635 214733 Revision A ...
Page 4: ...1026636 214733 Revision A ...
Page 44: ......
Page 287: ...214733 271 Revision A 5 5 5 Electrical System Module Layout MAINTENANCE AND SERVICING ...
Page 288: ......
Page 289: ...MAINTENANCE AND SERVICING Module Locations 1024956 A B C D E F G H J 214733 273 Revision A ...
Page 418: ......
Page 514: ......
Page 526: ......