214733
488
Revision A
J1939
SPN
J1939
FMI
Telltale
Lamp
Cummins
Fault Code
J1939_SPN Description
Detail
3512
3
Check
Engine
Amber
2185
Sensor supply voltage 4
Sensor Supply 4 Circuit - Voltage
above normal, or shorted to high
source
3512
4
Check
Engine
Amber
2186
Sensor supply voltage 4
Sensor Supply 4 Circuit - Voltage
below normal, or shorted to low
source
3513
3
Check
Engine
Amber
1695
Sensor supply voltage 5
Sensor Supply 5 - Voltage above
normal, or shorted to high source
3513
4
Check
Engine
Amber
1696
Sensor supply voltage 5
Sensor Supply 5 - Voltage below
normal, or shorted to low source
3514
3
Check
Engine
Amber
515
Sensor supply voltage 6
Sensor Supply 6 Circuit - Voltage
above normal, or shorted to high
source
3514
4
Check
Engine
Amber
516
Sensor supply voltage 6
Sensor Supply 6 Circuit - Voltage
below normal, or shorted to low
source
3515
5
Check
Engine
Amber
4743
Aftertreatment 1 Diesel
Exhaust Fluid
Temperature 2
Aftertreatment 1 Diesel Exhaust
Fluid Temperature 2 Sensor
Circuit - Current below normal or
open circuit
3515
6
Check
Engine
Amber
4744
Aftertreatment 1 Diesel
Exhaust Fluid
Temperature 2
Aftertreatment 1 Diesel Exhaust
Fluid Temperature 2 Sensor
Circuit - Current above normal or
grounded
3515
10
Check
Engine
None
6619
Aftertreatment 1 Diesel
Exhaust Fluid
Temperature 2
Aftertreatment 1 Diesel Exhaust
Fluid Temperature 2 - Abnormal
Rate of Change
3515
11
Check
Engine
Amber
4745
Aftertreatment 1 Diesel
Exhaust Fluid
Temperature 2
Aftertreatment 1 Diesel Exhaust
Fluid Temperature 2 - Root Cause
Not Known
3521
11
Check
Engine
Amber
4768
Aftertreatment 1 Diesel
Exhaust Fluid Property
Aftertreatment 1 Diesel Exhaust
Fluid Property - Root Cause Not
Known
3597
2
Check
Engine
None
1117
ECU Power Output Supply
Voltage #1
Power Supply Lost With Ignition
On - Data is erratic, intermittent,
or incorrect
3597
12
Check
Engine
Amber
351
ECU Power Output Supply
Voltage #1
Injector Power Supply - Bad
intelligent device or component
3597
17
Check
Engine
None
6499
ECU Power Output Supply
Voltage #1
ECU Power Output Supply
Voltage 1 - Data valid but below
normal operating range -
Moderately Severe Level
3597
18
Check
Engine
Amber
1938
ECU Power Output Supply
Voltage #1
ECU Power Output Supply
Voltage 1 - Data valid but below
normal operating range -
Moderately Severe Level
Summary of Contents for M1170
Page 3: ...Declaration of Conformity 1026635 214733 Revision A ...
Page 4: ...1026636 214733 Revision A ...
Page 44: ......
Page 287: ...214733 271 Revision A 5 5 5 Electrical System Module Layout MAINTENANCE AND SERVICING ...
Page 288: ......
Page 289: ...MAINTENANCE AND SERVICING Module Locations 1024956 A B C D E F G H J 214733 273 Revision A ...
Page 418: ......
Page 514: ......
Page 526: ......