214733
299
Revision A
1022381
A
B
C
Figure 5.63: Fresh Air Intake Filter
4.
Turn knob (A) counterclockwise, and remove it.
5.
Remove air filter retainer (B).
6.
Remove air filter (C).
Inspecting and Cleaning Fresh Air Intake Filter Element
1.
Tap the sides of the filter element gently to loosen dirt. Do
NOT
tap element against a hard surface.
2.
Using a dry element cleaner gun, clean element with compressed air.
IMPORTANT:
Air pressure must
NOT
exceed 414 kPa (60 psi). Do
NOT
direct air against outside of element, as dirt might be forced
through to the inside.
3.
Hold the air nozzle next to the filter element
’
s inner surface and move up and down the pleats.
4.
Repeat previous steps to remove additional dirt as required.
5.
Hold a bright light inside the element and check carefully for holes. Discard any element that shows the slightest hole.
6.
Check outer screen for dents. Vibration would quickly wear a hole in the filter.
7.
Check filter gasket for cracks, tears, or other signs of damage. If gasket is damaged or missing, replace element.
Summary of Contents for M1170
Page 3: ...Declaration of Conformity 1026635 214733 Revision A ...
Page 4: ...1026636 214733 Revision A ...
Page 44: ......
Page 287: ...214733 271 Revision A 5 5 5 Electrical System Module Layout MAINTENANCE AND SERVICING ...
Page 288: ......
Page 289: ...MAINTENANCE AND SERVICING Module Locations 1024956 A B C D E F G H J 214733 273 Revision A ...
Page 418: ......
Page 514: ......
Page 526: ......