214733
433
Revision A
Fault
Codes
Telltale
Short
Description
Full
Fault
Description
Recommended
Fix/Check
Message
SA
SPN
FMI
104
521036
8
Electrical
Syst
e
m
Right
Float
Cyl.
Vref
Err
or
Reference
voltage
err
or
.
Check
sensor
wiring
for
damage.
104
521039
3
Electrical
Syst
e
m
Knife
Pressure
Low
Alarm
Sensor
voltage
below
0.5
V.
Check
sensor
power
supply
and
replace
sensor
as
necessary
.
104
521039
4
Electrical
Syst
e
m
Knife
Pressure
High
Alarm
Sensor
voltage
above
4.5
V.
Check
for
wiring
damage
and
replace
sensor
as
necessary
.
104
521039
5
Electrical
Syst
e
m
Knife
Pressure
Low
Err
or
Sensor
voltage
below
0.5
V.
Check
sensor
power
supply
and
replace
sensor
as
necessary
.
104
521039
6
Electrical
Syst
e
m
Knife
Pressure
High
Err
or
Sensor
voltage
above
4.5
V.
Check
for
wiring
damage
and
replace
sensor
as
necessary
.
104
521039
8
Electrical
Syst
e
m
Knife
Pressure
Vref
Err
or
Reference
voltage
err
or
.
Check
sensor
wiring
for
damage.
104
521042
3
Electrical
Syst
e
m
Reel
Pressure
Low
Alarm
Sensor
voltage
below
0.5
V.
Check
sensor
power
supply
.
Adjus
t
and
re-calibrat
e
o
r
Replace
sensor
if
necessary
.
104
521042
4
Electrical
Syst
e
m
Reel
Pressure
High
Alarm
Sensor
voltage
above
4.5
V.
Check
for
wiring
damage.
Adjus
t
and
re-calibrate
o
r
Replace
sensor
if
necessary
.
104
521042
5
Electrical
Syst
e
m
Reel
Pressure
Low
Err
or
Sensor
voltage
below
0.5
V.
Check
sensor
power
supply
.
Adjus
t
and
re-calibrat
e
o
r
Replace
sensor
if
necessary
.
104
521042
6
Electrical
Syst
e
m
Reel
Pressure
High
Err
or
Sensor
voltage
above
4.5
V.
Check
for
wiring
damage.
Adjus
t
and
re-calibrate
o
r
Replace
sensor
if
necessary
.
104
521042
8
Electrical
Syst
e
m
Reel
Pressure
Vref
Err
or
Reference
voltage
err
or
.
Check
sensor
wiring
for
damage.
104
521045
3
Electrical
Syst
e
m
Header
Tilt
Low
Alarm
Sensor
voltage
below
0.5
V.
Check
sensor
power
supply
.
Adjus
t
and
re-calibrat
e
o
r
Replace
sensor
if
necessary
.
104
521045
4
Electrical
Syst
e
m
Header
Tilt
High
Alarm
Sensor
voltage
above
4.5
V.
Check
for
wiring
damage.
Adjus
t
and
re-calibrate
o
r
Replace
sensor
if
necessary
.
Summary of Contents for M1170
Page 3: ...Declaration of Conformity 1026635 214733 Revision A ...
Page 4: ...1026636 214733 Revision A ...
Page 44: ......
Page 287: ...214733 271 Revision A 5 5 5 Electrical System Module Layout MAINTENANCE AND SERVICING ...
Page 288: ......
Page 289: ...MAINTENANCE AND SERVICING Module Locations 1024956 A B C D E F G H J 214733 273 Revision A ...
Page 418: ......
Page 514: ......
Page 526: ......