214733
121
Revision A
Engine Oil Pressure
The nominal engine oil pressure is 69 kPa (10 psi) at low idle and 380 kPa (55.1 psi) at maximum rated speed.
If the oil pressure drops below the preset level of 52 kPa (7.5 psi), the Harvest Performance Tracker (HPT) displays an
engine telltale fault code to identify the issue.
If the red STOP ENGINE light illuminates, stop the engine
IMMEDIATELY
and investigate.
If the amber CAUTION light illuminates, stopping immediately is optional. You may continue operations and investigate
later, but you are
STRONGLY
advised to monitor the situation carefully.
Exhaust System Cleaning
The exhaust aftertreatment system uses diesel exhaust fluid (DEF) and selective catalyst reduction (SCR) technology to
reduce the emission of nitrogen oxides (NOx). The process involves injecting DEF (a nitrogenous compound which
decomposes into ammonia) into the exhaust over a catalyst. The ammonia reacts with NOx, producing harmless nitrogen
and water.
Automatic exhaust system cleaning events maintain the performance of the aftertreatment system by increasing exhaust
temperatures in order to remove the buildup of crystallized DEF. Automatic cleaning occurs any time during machine
operation as long as the INHIBIT SCR CONDITIONING switch is OFF. Turn on the INHIBIT SCR CONDITIONING switch if the
environment is not suitable for high exhaust temperatures (e.g., inside a building). The INHIBIT SCR CONDITIONING switch
is intended as a temporary measure. If the INHIBIT switch is left on for an extended period, the engine will derate until
manual SCR conditioning is performed.
Activate the MANUAL SCR CONDITIONING exhaust system cleaning if the automatic exhaust system cleaning was
deactivated during normal operation. Engine speed may vary between 1000 and 1400 rpm during manual exhaust system
cleaning.
Summary of Contents for M1170
Page 3: ...Declaration of Conformity 1026635 214733 Revision A ...
Page 4: ...1026636 214733 Revision A ...
Page 44: ......
Page 287: ...214733 271 Revision A 5 5 5 Electrical System Module Layout MAINTENANCE AND SERVICING ...
Page 288: ......
Page 289: ...MAINTENANCE AND SERVICING Module Locations 1024956 A B C D E F G H J 214733 273 Revision A ...
Page 418: ......
Page 514: ......
Page 526: ......