214733
420
Revision A
8.1.3
O-Ring Boss (ORB) Hydraulic Fittings (Adjustable)
1003431
A
B
C
D
Figure 8.6: Hydraulic Fitting
1.
Inspect O-ring (A) and seat (B) for dirt or obvious defects.
2.
Back off lock nut (C) as far as possible. Ensure that
washer (D) is loose and is pushed toward lock nut (C) as far
as possible.
3.
Check that O-ring (A) is
NOT
on threads and adjust if
necessary.
4.
Apply hydraulic system oil to O-ring (A).
1003432
D
A
E
B
C
Figure 8.7: Hydraulic Fitting
5.
Install fitting (B) into port until back up washer (D) and O-
ring (A) contact part face (E).
6.
Position angle fittings by unscrewing no more than
one turn.
7.
Turn lock nut (C) down to washer (D) and tighten to torque
shown. Use two wrenches, one on fitting (B) and other on
lock nut (C).
8.
Check final condition of fitting.