Appendix IV
____________________________________________________________________________________________
62 | Installation, Operation & Maintenance Instructions EASYCHLORGEN
2.7 DLFC (drain line flow control)
This is possibly one of the most important components to check has been installed; this will
control the backwash flow rate and ensure the system will continue to function correctly.
The DLFC is fitted inside the drain line elbow. See below picture of the drain line housing.
¾” Elbow
Insert
2.8 Injector
The injector is another important item in the functioning of the system, please check
that it is fitted in the DN position and that the UP position has been plugged. The
injector colour code is orange.
2.9 Electrical connections