background image

56L/MIN WALL MOUNTING DIESEL/FLUID 

TRANSFER SYSTEM WITH METER

MODEL NO: 

TP955.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

 

 

‰

  

WARNING!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

 

products. You may obtain an RCD by contacting your local Sealey stockist. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 

Appliance Test) tested.

 

Electrical safety information, it is important that the following information is read and understood.

 

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

 

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

 Important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the  

 

 

correct fuse - see fuse rating in these instructions.

 

8

   DO  NOT

 pull or carry the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable. 

 

8

   DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or is 

  replaced immediately by a qualified electrician.

 

 If the cable or plug is damaged during use, switch off the electricity supply and remove from use. 

        

 Ensure that repairs are carried out by a qualified electrician.

        

 Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

 a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

 b) Connect the BROWN live wire to the live terminal ‘L’.

 

 c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

       

 Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

 Sealey recommend that repairs are carried out by a qualified electrician.

1.1. 

  

GENERAL SAFETY

 WARNING!

 Ensure Health & Safety, government and local authority regulations relating to the transfer of  

 

 

diesel are adhered to when using this equipment. Familiarise yourself with the application, limitations and specific hazards peculiar to the  

 pump.

 

‰

   WARNING!

 Disconnect pump from the mains power before changing accessories, servicing or performing any maintenance.

 

   DANGER: DO NOT

 use pump for the transfer of fluid other than diesel fuel of a viscosity from 2 to 5.35 cSt at 37.8

O

C, with a minimum  

  flash point (PM) of >55

O

C, or for any other purpose.

 

   DANGER: Motor is not explosion proof and must not be used where flammable vapours may be present.

 

‰

   WARNING! On first use or after running out of fuel perform the following:

 

Switch on power and squeeze and release the trigger to attempt to discharge fuel for max. 2 minutes. If no fuel flows remove  

 

 

nozzle from dispensing hose and run pump again for max. 2 mins. 

DO NOT 

allow pump to run for more than 2 minutes if no fuel  

 

 

flows out - refer to instruction manual. 

RUNNING PUMP WITH NO FUEL FLOW FOR OVER  MINS. CAUSES INTERNAL DAMAGE.

 

9

   Filters (if fitted) should be changed regularly to ensure unrestricted fuel flow.

 

9

   Maintain pump in good condition (use authorised service agent). Drain meter and pipes before dismantling.

 

9

   Ensure unit is correctly calibrated before use, and after having been dismantling for maintenance.

 

9

   Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

 

9

   Ensure the transfer area is free of clutter and has adequate lighting.

 

9

   The motor is equipped with a thermal cut-out which will shut the motor off should the unit over heat. If this happens, turn the unit off and  

  allow to cool, by which time the cut-out will automatically reset.

 

9

   Keep children and unauthorised persons away from the working area.

 

9

   Replace/repair damaged parts. Use genuine parts. Unauthorised parts are dangerous and will invalidate warranty.

 

9

   Installation site must protect the unit from the weather.

 

9

   Retain manual with the unit for reference for any new user.

 

8

 

  DO NOT 

use the pump without the delivery nozzle attached.

 

8

  

DO NOT 

start or stop the pump by switching on or off at the mains power supply.

 

8

  

DO NOT

 use to dispense: petrol, inflammable liquieds, water, food liquids, liquids with viscosity>20 cSt, corrosive chemical products,  

 solvents.

 

8

 

  DO NOT 

operate the unit with wet hands. We recommend the use of diesel resistant gloves and goggles.

Refer to 

instruction

manual

Wear 

protective 

gloves

Wear protective 

clothing

TP955.V2  Issue:2 (H,F) 12/10/21

Original Language Version

© Jack Sealey Limited

Recommended fuse rating

13 Amp

Wear 

eye 

protection

Summary of Contents for TP955.V2

Page 1: ... that repairs are carried out by a qualified electrician 1 1 GENERAL SAFETY WARNING Ensure Health Safety government and local authority regulations relating to the transfer of diesel are adhered to when using this equipment Familiarise yourself with the application limitations and specific hazards peculiar to the pump WARNING Disconnect pump from the mains power before changing accessories servici...

Page 2: ...elling in the event of bad weather The installation of the dispenser must be carried out by skilled personnel and performed according to the instructions provided in this manual 5 2 MECHANICAL INSTALLATION fig 1 Before beginning the installation verify that no packing material has been trapped in the tubing Prepare suitable stilts or fixing brackets depending on the fixing position of the unit The...

Page 3: ...the pump should be partially filled with diesel fuel before turning it on for the first time 5 5 2 Priming the pump It is advisable to oversee the first priming phase to make sure that it is happening in a reasonable amount of time Depending on the length and fill status of the priming tubes the priming of the pump can require from several seconds to several minutes Recommendations and Warnings If...

Page 4: ...hree cross head screws on the right side of the unit B Lift off the top cover To reclose it perform these steps in reverse order 7 2 PERIODIC INSPECTIONS Weekly checks keep the pump body tubing and flanges clean to promptly reveal any leaks Keep the dispensing nozzle tube clean and especially the hole for the excess pressure probe at the end of the nozzle tube fig 6 With equal frequency or at leas...

Page 5: ...ation 8 TROUBLESHOOTING Problem Possible causes Solution Motor not turning Lack of electric power Set the starting handle to position ON Reset the external residual current circuit breaker Check the electrical connections Fuses burned out Replace the fuses in the electric panel Faulty switch on the electric panel Change the switch Motor problems If the rotor is jammed dismount and check for damage...