Appendix IV
____________________________________________________________________________________________
66 | Installation, Operation & Maintenance Instructions EASYCHLORGEN
3. Your System
3.1 Identifying your System
Your System will have an identification label fixed to the control valve, this will look similar to
the picture shown here.
The information listed can be read as follows:
Stock Number:
Serial No:
Id Code:
Configuration:
Manufacturers part number.
Serial No.
System type identification code
(= softener.)
Vessel size, Valve type & Controller type.
Identify the settings from the chart in the programming section – vessel size “
1665
”.
Each 16” diameter vessel requires a maximum of 150 litres of softener resin.
The duplex 1665 softener system is capable of treating a water volume of up to 18m
3
at a
hardness of 400 ppm CaCO3. Lower water hardness value results in an increase of water volume
that can be treated pro-rata, e.g.:
Each vessel regeneration will consume 24kg of salt.
The maximum peak flow of the softener system must not exceed 6.4m
3
/h
The valve is supplied pre-programmed!
(excluding settings that need to be done on site)
The settings are listed in case there is a need to re program the valve.
If you have any concerns or worries following the setting procedure please contact your
supplier who will help you through the set up procedures.
Using the above information to identify your system you can then select the relevant
setting sheet from the following pages.
4202035013
S/no 03100137
Soft