P30P-09A 16 User's manual
Settings
Mbus 485
RS-485
interface
parameters
Address
Device
address
ModeUnit
Frame type
BaudRate
Baud rate
Base.Reg
Base
register
number
(Master
mode)
No.ofVal
Number of
the queried
values
(Master
mode)
ValType
Type of the
queried
values
(Master
mode)
Interv.
Query
period
(Master
mode)
AnswTime
Max.
response
time (Master
mode)
Mode
Interface RS-
485 operating
mode
Mast.Fun
Selection of
the function
type for the
interface
operation in
Master mode
No.OfErr
Allowed
number of
the failed
queries for
RS-485
Master mode
Settings
Archive
Archiving
parameters
Arch.Val
Archived
values
selection
Param.Ar
Value type
triggerining
conditional
archiving
Ar.Mode
Archiving
type
OverLoAr
Archiving
lower limit
OverHiAr
Archiving
upper limit
Ar. Time
Archiving
period
Ar.Erase
Deleting an
internal
archive
Rec.ToSD
Override
allowing for
copying of
the internal
archive to
SD/SDHC
card
Param.SD
The
percentage of
the internal
archive space
used which
triggers
automatic
writing on
SD/SDHC
card
Settings
Support
service
parameters
Fabr.Par
Enter
standard
parameters.
Security
Enter a
password
Time
Setting the
current time
Date
Setting the
current date
AutoTime
Automatic
DST and
inversely
DispTest
LCD display
and LED
indicators
test
Language
Menu
language
selection
SaveFile
Override
allowing for
saving the
configuratio
n file to
SD/SDHC
card
Settings
Ethernet
Ethernet
interface para-
meters
DHCP
Enable/
disable
DHCP client
addrIP32
B3,B2 byte
of IP
address
(IPv4)
addrIP10
B1,B0 byte
of IP
address
(IPv4)
Mask 32
B3,B2 byte
of the
subnet
mask
Mask10
B1,B0 byte of
the subnet
mask
gate 32
B3,B2 byte
of the default
gateway
address
Gate 10
B1,B0 byte
of the
default
gateway
address
MAC 54
B5,B4 byte
of the
transducer
MAC
address
MAC 32
B3,B2 byte
of the
transducer
MAC
address
MAC 10
B1,B0 byte of
the
transducer
MAC address
acquired from DHCP or entered manually when DHCP is off, format: B3.B2.B1.B0
format : B5:B4:B3:B2:B1:B0
AddrmTCP
Device
address for
Modbus
TCP/IP
service
PortMbus
Modbus
TCP/IP port
TimeMbus
Port closing
time of
Modbus
TCP/IP
service port
if idle [s]
no.c.TCP
The number
of allowed
simultaneou
s
connections
to Modbus
TCP/IP
service
p.comFTP
FTP server
command
port
portFTP
FTP server
data port
portHTTP
Web server
port number
BaudRate
Baud rate
EthStdPa
Setting the
new
parameters
of Ethernet
interface
ReInitEt
Executing the
changes in
the Ethernet
interface
parameters
Fig.8 Programming matrix
5.4.1. Type of selected parameter value change
To increase the value of selected parameter, press the following button:
. Pressing
the button once increases the value by 1. Increasing the value by one when 9 is displayed, changes this
number to 0. Number is changed after the following button is pressed:
. Pressing the button
during the most important number allows to change the number sign after the following button is
pressed:
.