P30P-09A 15 User's manual
password starts programming matrix. The Fig. 8. shows the transition matrix in the programming mode.
Buttons allow the selection of the menu level and moving through the sublevel parameters
or
. Parameter symbol is displayed in the upper display line, the parameter itself is displayed in the
lower line. To edit a given parameter, press the following button:
. To cancel the parameter
change, press the following button:
. To exit the programming matrix and enter the
measurement mode, press and hold the following button:
. If the transducer is left in the
parameter programming mode, after 30 seconds it will exit programming mode and start to display the
displayed value.
Settings
Input
Parameters of
the main input
Inp.
Type
Current
measuremen
t range
selection 1A /
5A
Meas.Mod
Results
interpretatio
n mode
selection
DemandTm
Method of
averaging
the P, S and
I averages.
Averag.
Instantaneo
us values
averaging
method.
Synchro.
Measurement
synchronizati
on type
selection
(acc. to U or
I)
I direct
Software
current
reversal
ability
Clear En
Energy
counters
erasing
Reset AV
Restart of
counting the
averaged
values
TempMeas
Enabling a
temperature
measurement
Primar.U
Voltage
transformer
primary
voltage
Second.U
Voltage
transformer
secondary
voltage
Primar.I
Current
transformer
primary
voltage
Second.I
Current
transformer
secondary
voltage
Settings
Display
Display
parameters
Bcklight
Time of a
display
panel
illumination
Bckl.Int
Intensity of
LCD
display
panel
illuminatio
n
Disp.Reg
Register
number
displayed
on
the bottom
line of the
display
MainDisp
Main
displayed
value
MainUnit
Main
displayed
value unit
Ind.Ch.A
Coefficient
„A” of the
individual
characteristic
Ind.Ch.B
Coefficient
„B” of the
individual
characteristi
c
Settings
Alarm 1
Alarm 1
parameters
Param.A1
Input value
type for
alarm 1
Type A1
Alarm type
1
OverLoA1
Alarm 1
lower limit
OverHiA1
Alarm 1
upper limit
DlyOnA1
Alarm 1
activation
delay
DlyOffA1
Alarm 1
deactivation
delay
OnLockA1
Alarm 1 re-
activation
delay
SgKeepA1
Alarm 1
signalization
latch
Settings
Alarm 2
Alarm 2
parameters
Param.A2
Input value
type for
alarm 1
Type A2
Alarm type
2
OverLoA2
Alarm 2
lower limit
OverHiA2
Alarm 2
upper limit
DlyOnA2
Alarm 2
activation
delay
DlyOffA2
Alarm 2
deactivation
delay
OnLockA2
Alarm 2 re-
activation
delay
SgKeepA2
Alarm 2
signalization
latch
Settings
Output
Output
parameters
(analog output
no2 parameters
available only
when the
transducer is
equipped with
an additional
output)
ParamAn1
Control value
of analog
output 1 type
AnIn Lo1
Input 1
lower limit
AnIn Hi1
Input 1
upper limit
AnOutLo1
Output 1
lower limit
AnOutHi1
Output 1
upper limit
OverSer1
Enabling an
overrun of
output 1
Parameters available only when the
OverSer1
option is
on
OvOutLo1
Output 1
lower limit
overrun
OvOutHi1
Output 1
upper limit
overrun
OvrOutL1
Output 1
expected
value when
the lower limit
is exceeded
OvrOutH1
Output 1
expected
value when
the upper limit
is exceeded
ParamAn2
Control value
of analog
output 2 type
AnIn Lo2
Input 2
lower limit
AnIn Hi2
Input 2
upper limit
AnOutLo2
Output 2
lower limit
AnOutHi2
Output 2
upper limit
OverSer2
Enabling an
overrun of
output 2
Parameters available only when the
OverSer2
option is
on
OvOutLo2
Output 2
lower limit
overrun
OvOutHi2
Output 2
upper limit
overrun
OvrOutL2
Output 2
expected
value when
the lower limit
is exceeded
OvrOutH2
Output 2
expected
value when
the upper limit
is exceeded