![LMI Technologies Gocator 2300 Series User Manual Download Page 305](http://html1.mh-extra.com/html/lmi-technologies/gocator-2300-series/gocator-2300-series_user-manual_1932188305.webp)
Gocator 2300 & 2880 Series
Protocols • Gocator Protocol • 305
Field
Type
Offset
Description
length
32u
0
Reply size including this field, in bytes.
id
16u
4
Reply identifier (0x4005).
status
32s
6
Reply status. For a list of status codes, see
Reply
List Files
The List Files command returns a list of the files in the sensor's file system.
Field
Type
Offset
Description
length
32u
0
Command size including this field, in bytes.
id
16u
4
Command identifier (0x101A).
extension[64]
char
6
Specifies the extension used to filter the list of files (does not
include the "."). If an empty string is used, then no filtering is
performed.
Command
Field
Type
Offset
Description
length
32u
0
Reply size including this field, in bytes.
id
16u
4
Reply identifier (0x101A).
status
32s
6
Reply status. For a list of status codes, see
count
32u
10
Number of file names.
fileNames[count][64]
char
14
File names.
Reply
Copy File
The Copy File command copies a file from a source to a destination within the connected sensor (a .job
file, a component of a job file, or another type of file; for more information, see
To make a job active (to load it), copy a saved job to "_live.job".
To "save" the active job, copy from "_live.job" to another file.
Field
Type
Offset
Description
length
32u
0
Command size including this field, in bytes.
id
16u
4
Command identifier (0x101B).
source[64]
char
6
Source file name.
destination[64]
char
70
Destination file name.
Command
Summary of Contents for Gocator 2300 Series
Page 1: ...USER MANUAL Gocator 2300 2880 Series Firmware version 4 3 x xx Document revision D ...
Page 20: ...Gocator 2300 2880 Series Getting Started System Overview 20 ...
Page 184: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 184 Measurement Panel ...
Page 189: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 189 ...
Page 199: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 199 Measurement Panel ...
Page 208: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 208 else Output_Set Volume 0 ...
Page 389: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 389 Dimensions Envelope ...
Page 392: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 392 Dimensions Envelope ...
Page 394: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 394 Envelope ...
Page 396: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 396 Dimensions ...
Page 397: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 397 Envelope ...
Page 399: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 399 Envelope ...
Page 401: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 401 Dimensions ...
Page 402: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 402 Envelope ...
Page 405: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 405 Dimensions ...
Page 406: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 406 Envelope ...