Gocator 2300 & 2880 Series
Gocator Device Files • Job Files • 246
Tracking
Element
Type
Description
Enabled
Bool
Enables tracking.
Enabled.used
Bool
Whether or not this field is used.
SearchThreshold
64f
Percentage of spots that must be found to remain in track.
Height
64f
Tracking window height (mm).
Height.min
64f
Minimum tracking window height (mm).
Height.max
64f
Maximum tracking window height (mm).
Tracking Child Elements
Material
Element
Type
Description
Type
32s
Type of Material settings to use.
0 – Custom
1 – Diffuse
Type.used
Bool
Determines if the setting’s value is currently used.
Type.value
32s
Value in use by the sensor, useful for determining value when used is
false.
SpotThreshold
32s
Spot detection threshold.
SpotThreshold.used
Bool
Determines if the setting’s value is currently used.
SpotThreshold.value
32s
Value in use by the sensor, useful for determining value when used is
false.
SpotWidthMax
32s
Spot detection maximum width.
SpotWidthMax.used
Bool
Determines if the setting’s value is currently used.
SpotWidthMax.value
32s
Value in use by the sensor, useful for determining value when used is
false.
SpotWidthMax.min
32s
Minimum allowed spot detection maximum value.
SpotWidthMax.max
32s
Maximum allowed spot detection maximum value.
SpotSelectionType
32s
Spot selection type
0 – Best. Picks the strongest spot in a given column.
1 – Top. Picks the spot which is most Top/Left on the imager
2 – Bottom. Picks the spot which is most Bottom/Right on the imager
3 – None. All spots are available. This option may not be available in
some configurations.
SpotSelectionType.used
Bool
Determines if the setting’s value is currently used.
SpotSelectionType.value
32s
Value in use by the sensor, useful for determining value when used is
false.
SpotSelectionType.options
32s (CSV)
List of available spot selection types.
Material Child Elements
Summary of Contents for Gocator 2300 Series
Page 1: ...USER MANUAL Gocator 2300 2880 Series Firmware version 4 3 x xx Document revision D ...
Page 20: ...Gocator 2300 2880 Series Getting Started System Overview 20 ...
Page 184: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 184 Measurement Panel ...
Page 189: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 189 ...
Page 199: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 199 Measurement Panel ...
Page 208: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 208 else Output_Set Volume 0 ...
Page 389: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 389 Dimensions Envelope ...
Page 392: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 392 Dimensions Envelope ...
Page 394: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 394 Envelope ...
Page 396: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 396 Dimensions ...
Page 397: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 397 Envelope ...
Page 399: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 399 Envelope ...
Page 401: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 401 Dimensions ...
Page 402: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 402 Envelope ...
Page 405: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 405 Dimensions ...
Page 406: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 406 Envelope ...