Gocator 2300 & 2880 Series
Gocator Device Files • Job Files • 290
Element
Type
Description
0 – 12-bit
1 – 12-bit with search
2 – 14-bit
3 – 14-bit with search
Format.options
32s (CSV)
List of available formats.
DataScaleMin
64f
Measurement value corresponding to minimum word value.
DataScaleMax
64f
Measurement value corresponding to maximum word value.
Ascii
Element
Type
Description
Delimiter
String
Field delimiter.
Terminator
String
Line terminator.
InvalidValue
String
String for invalid output.
CustomDataFormat
String
Custom data format.
CustomFormatEnabled
Bool
Enables custom data format.
Ascii Child Elements
Transform
The transformation component contains information about the physical system setup that is used to:
l
Transform data from sensor coordinate system to another coordinate system (e.g., world)
l
Define encoder resolution for encoder-based triggering
l
Define the travel offset (Y offset) between sensors for staggered operation
You can access the Transform component of the active job as an XML file, either using path notation, via
"_live.job/transform.xml", or directly via "_live.tfm".
You can access the Transform component in user-created job files in non-volatile storage, for example,
"productionRun01.job/transform.xml". You can only access transformations in user-created job files
using path notation.
See the following sections for the elements contained in this component.
Transformation Example:
<?xml version="1.0" encoding="UTF-8"?>
<Transform version="100">
<EncoderResolution>1</EncoderResolution>
<Speed>100</Speed>
<Devices>
<Device role="0">
<X>-2.3650924829</X>
Summary of Contents for Gocator 2300 Series
Page 1: ...USER MANUAL Gocator 2300 2880 Series Firmware version 4 3 x xx Document revision D ...
Page 20: ...Gocator 2300 2880 Series Getting Started System Overview 20 ...
Page 184: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 184 Measurement Panel ...
Page 189: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 189 ...
Page 199: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 199 Measurement Panel ...
Page 208: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 208 else Output_Set Volume 0 ...
Page 389: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 389 Dimensions Envelope ...
Page 392: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 392 Dimensions Envelope ...
Page 394: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 394 Envelope ...
Page 396: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 396 Dimensions ...
Page 397: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 397 Envelope ...
Page 399: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 399 Envelope ...
Page 401: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 401 Dimensions ...
Page 402: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 402 Envelope ...
Page 405: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 405 Dimensions ...
Page 406: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 406 Envelope ...