Gocator 2300 & 2880 Series
Gocator Web Interface • Measurement • 173
Multiple measurements can be performed on the entire surface or each discrete object, limited only by
the available CPU resources.
The frame of reference for the coordinate system of the detected object can be set to
Sensor
or
Part
in
the
Part Detection
panel (see on page 103). This setting determines what coordinate system the region
of interest for a measurement is positioned in, as well as the coordinate reference used to output
measurement values.
For example, if you need to measure the average height in a certain location relative to the sensor's field
of view regardless of the objects passing under the sensor, the frame of reference should be set to
Sensor
. This is typical in applications where a wide web of material is continuously scanned, such as
paper, rubber, fabrics, etc. If on the other hand you need to measure the average height in a certain
location of a scanned object, the frame of reference should be set to
Part
. This is typical in applications
where discrete objects pass under the sensor and specific locations on the objects need to be inspected.
Measurement Tools
Bounding Box
The Bounding Box tool provides measurements related to the smallest rectangle box that encapsulates
the part (for example, X position, Y position, width, length, etc.).
The measurement value can be compared with minimum and maximum constraints to yield a decision.
on page 134 for instructions on how to add measurement tools.
A bounding box can be vertical or rotated. A vertical bounding box provides the absolute position from
which the Position centroids tools are referenced.
The vertical bounding box X and Y correspond to the part frame of reference origin. For this
reason all X and Y measurements (except Bounding Box GlobalX and GlobalY) are referenced
to this point when
Summary of Contents for Gocator 2300 Series
Page 1: ...USER MANUAL Gocator 2300 2880 Series Firmware version 4 3 x xx Document revision D ...
Page 20: ...Gocator 2300 2880 Series Getting Started System Overview 20 ...
Page 184: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 184 Measurement Panel ...
Page 189: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 189 ...
Page 199: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 199 Measurement Panel ...
Page 208: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 208 else Output_Set Volume 0 ...
Page 389: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 389 Dimensions Envelope ...
Page 392: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 392 Dimensions Envelope ...
Page 394: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 394 Envelope ...
Page 396: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 396 Dimensions ...
Page 397: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 397 Envelope ...
Page 399: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 399 Envelope ...
Page 401: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 401 Dimensions ...
Page 402: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 402 Envelope ...
Page 405: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 405 Dimensions ...
Page 406: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 406 Envelope ...