![LMI Technologies Gocator 2300 Series User Manual Download Page 138](http://html1.mh-extra.com/html/lmi-technologies/gocator-2300-series/gocator-2300-series_user-manual_1932188138.webp)
Gocator 2300 & 2880 Series
Gocator Web Interface • Measurement • 138
5.
Click in the ID field.
6.
Enter a new ID number.
The value must be unique among all measurements.
7.
Press the Tab or Enter key, or click outside the ID field.
The measurement ID will be changed.
Common Measurement Settings
All tools provide region settings under the
Parameter
tab, and all measurements provide decision and
filter settings under the
Output
tab.
Many tools and measurements also have tool- and measurement-specific parameters. See the individual
measurement tools for details.
Source
For dual-sensor systems, you must specify a profile source for tools. The source determines which
sensor provides data for the measurement.
Depending on the layout you have selected, the
Source
drop-down will display one of the following (or a
combination). For more information on layouts, see
Setting
Description
Top
Refers to the Main sensor in a standalone or dual-sensor system, the Main sensor in
Opposite layout, or the combined data from both Main and Buddy sensors.
Bottom
Refers to a Buddy sensor in a dual-sensor system position in Opposite layout.
Top Left
Refers to a Main sensor in Wide layout or to a Buddy sensor in Reverse layout in a
dual-sensor system position.
Top Right
Refers to a Buddy sensor in Wide layout or to a Main sensor in Reverse layout in a
dual-sensor system position.
To select the source:
1.
Go to the
Scan
page.
2.
Choose Profile or Surface mode in the
Scan Mode
panel, depending on the type of measurement
whose decision you need to configure.
If one of these modes is not selected, tools will not be available in the
Measure
panel.
3.
Go to the
Measure
page by clicking on the
Measure
icon.
4.
In the
Tools
panel, click on a tool in the tool list.
5.
Click on the
Parameter
tab in the tool configuration area.
6.
Select the profile source in the
Source
drop-down list.
Summary of Contents for Gocator 2300 Series
Page 1: ...USER MANUAL Gocator 2300 2880 Series Firmware version 4 3 x xx Document revision D ...
Page 20: ...Gocator 2300 2880 Series Getting Started System Overview 20 ...
Page 184: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 184 Measurement Panel ...
Page 189: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 189 ...
Page 199: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 199 Measurement Panel ...
Page 208: ...Gocator 2300 2880 Series Gocator Web Interface Measurement 208 else Output_Set Volume 0 ...
Page 389: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 389 Dimensions Envelope ...
Page 392: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 392 Dimensions Envelope ...
Page 394: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 394 Envelope ...
Page 396: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 396 Dimensions ...
Page 397: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 397 Envelope ...
Page 399: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 399 Envelope ...
Page 401: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 401 Dimensions ...
Page 402: ...Gocator 2300 2880 Series Specifications Gocator 2300 Series 402 Envelope ...
Page 405: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 405 Dimensions ...
Page 406: ...Gocator 2300 2880 Series Specifications Gocator 2880 Sensor 406 Envelope ...