7.2.1.1 X4.3 Brake Operation Enabled Behavior
The following figure shows the behavior when only the brake mode “Status Word: Operation
Enabled” is selected. If only this switch (with UPID 1717h) is activated, no apply or release
delay time is regarded.
7.2.1.2 X4.3 Brake Operation /Abort Behavior
When set the brake mode to “Ctrl Word: /Abort”, the brake is applied in state Aborting (12)
and the maximal current of the motor is set to 0A. If using this behavior, ensure that the
maximal current (UPID 13A6h and 13BAh) is not set over a serial bus during the state
Aborting (12)!
Parameter Name
UPID
Description
Apply Delay
Time
171Bh
Delay time after brake output goes to 0V until the maximal
current of the motor is set to 0A (UPID 13A6h and 13BAh).
Release Delay
Time
171Ch
Delay time of the Status Word bit: Operation Enabled after
the motion has stopped.
Page 72/91
User Manual Motion Control SW / 06/12/2013
NTI AG / LinMot
Operation Enabled
Brake Out X4.3
Operation Enabled
Brake Out X4.3
/Abort
Stopping
Apply Delay Time
Maximal Current
Release Delay Time