L
i
n
M
o
t
Motion Control SW
1. Par
2
Position Increment
SInt16 Scaled
2. Par
4
Maximal Velocity
UInt16 Scaled
3. Par
6
Acceleration
UInt16 Scaled
4. Par
8
Deceleration
UInt16 Scaled
4.3.72
VAI 16 Bit Go To Pos From Act Pos And Act Vel (093xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
093xh: VAI 16 Bit Go To Pos From Act Pos And Act
Vel
UInt16 -
1. Par
2
Target Position
SInt16 Scaled
2. Par
4
Maximal Velocity
UInt16 Scaled
3. Par
6
Acceleration
UInt16 Scaled
4. Par
8
Deceleration
UInt16 Scaled
This command starts the new VAI setpoint generation from the actual position, can be used
after a press command.
4.3.73
VAI 16 Bit Go To Pos From Act Pos Starting With Dem Vel = 0
(094xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
094xh: VAI 16 Bit Go To Pos From Act Pos Starting
With Dem Vel = 0
UInt16 -
1. Par
2
Target Position
SInt16 Scaled
2. Par
4
Maximal Velocity
UInt16 Scaled
3. Par
6
Acceleration
UInt16 Scaled
4. Par
8
Deceleration
UInt16 Scaled
This command starts a the new VAI-Setpoint generation from the actual position and the
start velocity is forced to zero. Can be used after a press command.
4.3.74
VAI 16 Bit Increment Act Pos (095xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
095xh: VAI 16 Bit Increment Act Pos
UInt16 -
1. Par
2
Position Increment
SInt16 Scaled
2. Par
4
Maximal Velocity
UInt16 Scaled
3. Par
6
Acceleration
UInt16 Scaled
4. Par
8
Deceleration
UInt16 Scaled
4.3.75
VAI 16 Bit Increment Act Pos Starting With Dem Vel = 0
(096xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
096xh: VAI 16 Bit Increment Act Pos
UInt16 -
1. Par
2
Position Increment
SInt16 Scaled
2. Par
4
Maximal Velocity
UInt16 Scaled
3. Par
6
Acceleration
UInt16 Scaled
4. Par
8
Deceleration
UInt16 Scaled