Motion Control SW
L
i
n
M
o
t
Can be used in a linked command table sequence.
4.3.151
Wait Until Demand Position Greater Than (220xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
220xh: Wait Until Demand Position Greater Than
UInt16
-
1. Par
2
Dem Pos Trig Level
SInt32
0.1 um
Can be used in a linked command table sequence.
4.3.152
Wait Until Demand Position Less Than (221xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
221xh: Wait Until Demand Position Less Than
UInt16
-
1. Par
2
Dem Pos Trig Level
SInt32
0.1 um
Can be used in a linked command table sequence.
4.3.153
Wait Until Actual Position Greater Than (222xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
222xh: Wait Until Actual Position Greater Than
UInt16
-
1. Par
2
Act Pos Trig Level
SInt32
0.1 um
Can be used in a linked command table sequence.
4.3.154
Wait Until Actual Position Less Than (223xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
223xh: Wait Until Actual Position Less Than
UInt16
-
1. Par
2
Act Pos Trig Level
SInt32
0.1 um
Can be used in a linked command table sequence.
4.3.155
Wait Until Difference Position Greater Than (224xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
224xh: Wait Until Difference Position Greater Than
UInt16
-
1. Par
2
Diff Pos Trig Level
SInt32
0.1 um
Can be used in a linked command table sequence.
4.3.156
Wait Until Difference Position Less Than (225xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
225xh: Wait Until Difference Position Less Than
UInt16
-
1. Par
2
Diff Pos Trig Level
SInt32
0.1 um
Can be used in a linked command table sequence.
NTI AG / LinMot
User Manual Motion Control SW/ 06/12/2013