Motion Control SW
L
i
n
M
o
t
4.3.163
Wait Until Current Greater Than (22Exh)
Name
Byte
Offset
Description
Type
Unit
Header
0
22Exh: Wait Until Current Greater Than
UInt16
-
1. Par
2
Dem Curr Vel Trig Level
Sint16
1mA
Can be used in linked command table sequence.
4.3.164
Wait Until Current Less Than (22Fxh)
Name
Byte
Offset
Description
Type
Unit
Header
0
22Fxh: Wait Until Current Less Than
UInt16
-
1. Par
2
Dem Curr Trig Level
Sint16
1mA
Can be used in a linked command table sequence.
4.3.165
Set Cmd Table Var 1 To (240xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
240xh: Set Cmd Table Var 1 To
UInt16
-
1. Par
2
Set value
Sint32
-
4.3.166
Add To Cmd Table Var 1 (241xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
241xh: Add To Cmd Table Var 1
UInt16
-
1. Par
2
Add value
Sint32
-
4.3.167
Set Cmd Table Var 2 To (242xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
242xh: Set Cmd Table Var 2 To
UInt16
-
1. Par
2
Set value
Sint32
-
4.3.168
Add To Cmd Table Var 2 (243xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
243xh: Add To Cmd Table Var 2
UInt16
-
1. Par
2
Add value
Sint32
-
4.3.169
Write Cmd Table Var 1 To UPID RAM value (248xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
248xh: Write Cmd Table Var 1 To UPID RAM value
UInt16 -
1. Par
2
UPID (Unique Parameter ID)
UInt16 -
4.3.170
Write Cmd Table Var 2 To UPID RAM value (249xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
249xh: Write Cmd Table Var 2 To UPID RAM value
UInt16 -
1. Par
2
UPID (Unique Parameter ID)
UInt16 -
NTI AG / LinMot
User Manual Motion Control SW/ 06/12/2013
Page 59/91