Motion Control SW
L
i
n
M
o
t
4.3.85
Predef VAI 16 Bit Increment Dem Pos (0A1xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0A1xh: Predef VAI 16 Bit Increment Dem Pos
UInt16
-
1. Par
2
Position Increment
SInt16
Scaled
4.3.86
Predef VAI 16 Bit Increment Target Pos (0A2xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0A2xh: Predef VAI 16 Bit Increment Target Pos
UInt16 -
1. Par
2
Position Increment
SInt16 Scaled
4.3.87
Predef VAI 16 Bit Go To Pos From Act Pos And Act Vel
(0A3xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0A3xh: VAI 16 Bit Go To Pos From Act Pos And
Act Vel
UInt16 -
1. Par
2
Target Position
SInt16 Scaled
This command starts a new VAI setpoint generation from the actual position, can be used
after a press command.
4.3.88
Predef VAI 16 Bit Go To Pos From Act Pos Starting With Dem
Vel = 0 (0A4xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0A4xh: Predef VAI 16 Bit Go To Pos From Act Pos
Starting With Dem Vel = 0
UInt16 -
1. Par
2
Target Position
SInt16 Scaled
This command starts a new VAI setpoint generation from the actual position and the start
velocity is forced to zero. Can be used after a press command.
4.3.89
Predef VAI 16 Bit Stop (0A7xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0A7xh: Predef VAI Stop With Quick Stop
Deceleration
UInt16 -
4.3.90
Predef VAI 16 Bit Go To Pos After Actual Command (0A8xh)
Name
Byte
Offset
Description
Type
Unit
Header
0
0A8xh: Predef VAI 16 Bit Go To Pos After Actual
Command
UInt16 -
1. Par
2
Target Position
SInt16 Scaled
This command waits until the actual motion setpoint generation has finished, then starts the
new defined VAI motion.
NTI AG / LinMot
User Manual Motion Control SW/ 06/12/2013
Page 45/91