L
i
n
M
o
t
Motion Control SW
Ah
X X IF Actual Position Less Than
Bh
X X IF Actual Greater Than
Ch
X X IF Difference Position Less Than
Dh
X X IF Difference Greater Than
Eh
X X IF Current Less Than
Fh
X X IF Current Greater Than
26h
0h
X X IF Analog Val On X4.4 Less Than
2h
X X IF Masked X4 Input Value Equal Than
3h
X
IF Masked X6 input Value Equal Than
4h
X X IF Masked Status Word Equal Than
5h
X X IF Masked Warn Word Equal Than
30h
0h
X X Encoder Winding Start With Default Parameters
1h
X X Encoder Winding Start With Default Parameters At Revolutions
4h
X X Encoder Winding Stop Adaptation Of Left, Right Position And
Disturbance
5h
X X Encoder Winding Restart Adaptation Of Left, Right Position And
Disturbance
31h
0h
X k Encoder Curve Winding Start With Default Parameters
1h
X k Encoder Curve Winding Start With Default Parameters At
Revolutions
38h
0h
f
f
VAI Go To Pos With Force Ctrl Limit
1h
f
f
VAI Go To Pos From Act Pos And Reset Force Control
2h
f
f
Force Ctrl Change Target Force
3h
f
f
VAI Go To Pos With Force Ctrl Limit and Target Force
4h
f
f
VAI Go To Pos With Lower Force Ctrl Limit
5h
f
f
VAI Go To Pos With Lower Force Ctrl Limit and Target Force
k: only with Curve Key available (B1100)
f: only with Force Control Key