AM58K CANopen®
7 – Setting-up
Here following are some examples of transmission between Master and Slave
devices.
A generic “ID” value is used to indicate the encoder address; Master address is
always 0. All values are expressed in hexadecimal notation.
Set
Operational
,
Pre-operational
state
NMT message
Master
Slave
COB-ID
Cmd
Node
Operational
:
000
01
ID
Pre-operational
:
000
80
ID
(2
10
=0000
0400h)
Master
Encoder (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
23
01
60
00
00
40
00
00
Encoder
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
01
60
00
00
00
00
00
(2
24
=0100 0000h)
Master
Encoder (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
23
02
60
00
00
00
00
01
Encoder
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
02
60
00
00
00
00
00
: CW,
: enabled,
: disabled)
Master
Encoder (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
2B
00
60
00
04
00
-
-
Encoder
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
00
60
00
00
00
-
-
MAN AM58K CB E 1.1.odt
49